INSTALLATION INSTRUCTIONS
SECURE THE LOWER SASH
Attach the right angle sash lock with 2 1/2" locking
screw.
It can be diffi cult to install the sash lock in vinyl-
clad windows. In these installations, the sash lock is
optional.
Cut the foam window seal to the width of the
window. Insert it into the space between the upper
and lower sashes.
CHECK INSTALLATION
The air conditioner should be angled downwards
toward the outside so that condensed water can
drain outside. If water is draining out the front of the
cabinet, check that the air conditioner is properly
angled.
The air conditioner should be tilted between 1/4
- 1/2", (between 2 - 4°) downward toward the
outside.
Wooden Window Sill
Vinyl-Clad Window Sill
16