Descargar Imprimir esta página

Firman T07571F Manual Del Operador página 23

Publicidad

Idiomas disponibles

Idiomas disponibles

5. Turn the LPG/NG selector switch to NG position.
6. Turn the main fuel selector switch to LPG/NG position.
NOTICE When the main fuel selector switch is turned to the LPG/NG position, the indicator light
will turn RED for up to 4 minutes (before going off). Starting the engine successfully anytime
during the 4 minutes will turn the indicator light GREEN. See Indicator light-Battery Power Saving
Mode section for more information.
7. Disconnect all electrical loads from the generator. Never start or stop the generator with
electrical devices plugged in.
8. Move choke lever located on engine to "START" position.
(For electric start move to step (12))
9. For recoil start only - PULL-TO-PRIME Pull the starter cord 1-2 times. Pull slowly until resistance
if felt and then pull rapidly.
English
1-2 Times
22
OPERATION
Customer Service: 1-844-FIRMAN1

Publicidad

loading