MODEL:
SL2500/B
SL2500/C
ENG |
INSTRUCTIONS
Before using or installing the product, kindly read the instructions and follow safety rules. Installation should
be provided by qualified person or company.
Thank you for choosing the item of company PANLUX s.r.o.
Technical data
Angle of detection: horizontal – 360°, vertical – 130°
Recommended installation height: 2,5m
Location: interiors, exteriors
Material: plastic
Notice
Before using, check the product and make sure that it is not damaged, otherwise do not use it. Before any manipulation make
sure that mains electrical supply is disconnected. In case of damage do not repair or disassemble the product. The incorrect
function of the product can be caused by interruption of electromagnetic field, small temperature difference between moving
object and surroundings, reflection (e.g. strong luminous source).
Infringement of any mentioned instruction can cause harm to health or property.
Installation
1
100 mm
80 mm
2
230V~50Hz
230V
TIME
SENS
IP44
~50Hz
Principle of PIR sensor
PIR sensor receives infra-red waves emitted by objects in reach radius. With movement in the detection area sensor notices
the change and initiates trigger order „Light on" for adjusted time.
Reach setting (sensitivity) – max. 6m
Reach is to be understood as the area traced out by angle of detection and min. to max. available distance from sensor.
Reach can be changed with rotation of sensors head.
Time setting (switch-off delay) – TIME (10s (±5s) až 4min (±1 min))
The countdown of adjusted time begins after last detected movement. We recommend setting the function on minimum
during functional test.
Twilight setting (response threshold) – LUX (2–2000lx)
We recommend setting the function on maximum during test.
Stated information may differ according to position and installation height.
Position marked - or  applies to minimum and position marked
Warranty voids if the product is mechanically damaged or connected unprofessionally.
3
4
5
L`
L
N
L
L
N
SENZOR SL2500
LUX
max. 300W
max. 1000W
3x2,5mm
or
applies to maximum.
+
5m
5m
2m
6m
6m
All right reserved.
Technical data can be changed without previous notice.
C
0,210kg
2
0m
2m
UM_SL2300_140709