DOUBLE INSULATION
Double insulation is a concept in safety in electric products,
which eliminates the need for the usual three-wire grounded
power cord. All exposed metal parts are isolated from the
internal metal motor components with protecting insulation.
Double insulated products do not need to be grounded.
WARNING:
The double insulated system is intended to protect the
user from shock resulting from a break in the product's
internal wiring. Observe all normal safety precautions to
avoid electrical shock.
NOTE: Servicing of a product with double insulation requires
extreme care and knowledge of the system and should
be performed only by a qualified service technician. For
service, we suggest you return the product to your nearest
authorized service center for repair. Always use original
factory replacement parts when servicing.
ELECTRICAL CONNECTION
This product should be connected to a power supply that
is 120 volts, AC only (normal household current), 60 Hz.
Do not operate this product on direct current (DC) through
the power cord. A substantial voltage drop will cause a loss
of power and the motor will overheat. If the product does
not operate when plugged into an outlet, double-check the
power supply.
EXTENSION CORDS
When using a product at a considerable distance from a
power source, be sure to use an extension cord that has
the capacity to handle the current the product will draw. An
undersized cord will cause a drop in line voltage, resulting in
overheating and loss of power. Use the chart to determine
CALIFORNIA PROPOSITION 65
WARNING:
This product may contain chemicals, including lead, known to the State of California to cause cancer, birth defects or
other reproductive harm. Wash hands after handling.
ELECTRICAL
the minimum wire size required in an extension cord. Only
round jacketed cords listed by Underwriter's Laboratories
(UL) should be used.
Use an extension cord that is designed for outside use. This
type of cord is designated with "WA" or "W" on the cord's
jacket.
Before using any extension cord, inspect it for loose or
exposed wires and cut or worn insulation.
**Ampere rating (on product data plate)
Cord Length
25´
50´
100´
**Used on 12 gauge - 20 amp circuit
NOTE: AWG = American Wire Gauge
WARNING:
Keep the extension cord clear of the working area.
Position the cord so that it will not get caught on lumber,
tools, or other obstructions while you are working with
this product. Failure to do so can result in serious
personal injury.
WARNING:
Check extension cords before each use. If damaged
replace immediately. Never use a product with a damaged
cord since touching the damaged area could cause
electrical shock resulting in serious injury.
4 – English
0-2.0
2.1-3.4
3.5-5.0
5.1-7.0
Wire Size (A.W.G.)
16
16
16
16
16
16
16
16
14
7.1-12.0 12.1-16.0
16
14
14
14
14
12
12
10
—