3. Specifications
3.3 Output signals
Switching output 1
EN
PNP
PNP
PNP
PNP
PNP
Alternatively also available with an NPN instead of a PNP switching output.
With the IO-Link option, switching output 1 is always PNP.
IO-Link, revision 1.1 (option)
IO-Link is optionally available for all output signals.
With the IO-Link option, switching output SP1 is always PNP.
Zero offset adjustment
maximum 3 % of span
Switching thresholds
Switch point 1 and switch point 2 are individually adjustable
Switching functions
Normally open, normally closed, window, hysteresis
Freely adjustable
Switching voltage
Power supply - 1 V
10
Switching output 2
-
-
PNP
PNP
PNP
WIKA operating instructions pressure switch, model PSD-3x
Analogue signal
4 ... 20 mA (3-wire)
DC 0 ... 10 V (3-wire)
-
4 ... 20 mA (3-wire)
DC 0 ... 10 V (3-wire)