FocusPRO
Thermostat Installation Guide
®
Installer setup tables
Setup function
36 Zone name
39 Wireless setup
90 RESET
Special functions
Heat Pump Control — Electric Backup (Setup Functions 24-25):
Heat Pump Control — Fossil Fuel Backup (Setup Function 18):
Note: If temperature is not reached in a reasonable time, set the upstage to furnace timer
(function 21). After the designated time, the compressor will turn off and the system will switch
to back up heat.
OPTION 0: NO DROOP CONTROL
COMPRESSOR AND
FAN ONLY
40
FOSSIL FUEL
BACKUP HEAT ONLY
1
IF ROOM TEMPERATURE DROPS (EXCEEDS DROOP SETTING AT FUNCTION 20), COMPRESSOR IS DEACTIVATED. FOSSIL FUEL
BACKUP HEAT IS ACTIVATED AFTER 3 MINUTE DELAY.
**
FOR GEOTHERMAL HEAT PUMPS, THE BALANCE POINT CAN BE DISABLED AT SETUP FUNCTION 24.
Comfort/Economy — Setup Function 26 (Not available when Setup Function 17 is set to 0):
If you choose Comfort, auxiliary heat will respond quickly to meet the temperature
setpoint. If you choose Economy, the system will wait longer. Auxiliary heat will be activated
only if the setpoint is not reached within a reasonable time.
69-2092EFS—11
Settings & options (factory default in bold)
52
Thermostat
1 Basement
2 Bathroom
3 Bathroom 1
4 Bathroom 2
5 Bathroom 3
6 Bedroom
7 Bedroom 1
8 Bedroom 2
9 Bedroom 3
10 Bedroom 4
11 Boat House
12 Bonus Room
13 Computer Room 28 Kitchen 2
14 Den
15 Dining Room
0
Disconnect thermostat from wireless system
1
Thermostat is connected to wireless system
0
No reset
1
Reset installer options & program schedule to factory default
settings
COMPRESSOR AND FAN ONLY
55
COMPRESSOR AND FAN OPERATE
1
40
ELECTRIC BACKUP HEAT AND FAN ONLY
1
IF THE COMPRESSOR CANNOT REACH OR MAINTAIN TEMPERATURE SETTING,
BOTH THE COMPRESSOR AND ELECTRIC BACKUP HEAT WILL OPERATE.
OPTION 1: DROOP CONTROL
COMPRESSOR AND
FAN OPERATE
1
BALANCE
40
FOSSIL FUEL
POINT **
BACKUP HEAT ONLY
16 Exercise Room
30 Library
17 Family Room
31 Living Room
18 Fireplace
32 Lower Level
19 Foyer
33 Master Bath
20 Game Room
34 Master Bed
21 Garage
35 Media Room
22 Great Room
36 Music Room
23 Guest Room
37 Nursery
24 Gym
38 Office
25 Kid's Room
39 Office 1
26 Kitchen
40 Office 2
27 Kitchen 1
41 Pantry
42 Play Room
29 Laundry Room
43 Pool Room
AUXILIARY LOCKOUT
COMPRESSOR LOCKOUT
OPTION 2: DROOP CONTROL WITH AUX HEAT LOCKOUT
COMPRESSOR AND FAN ONLY
55
COMPRESSOR AND FAN OPERATE
BALANCE
40
POINT **
FOSSIL FUEL BACKUP HEAT ONLY
6
44 Porch
45 Rec Room
46 Sewing Room
47 Spa
48 Storage Room
49 Studio
50 Sun Room
51 Theater
52 Thermostat
53 Upper Level
54 Utility Room
55 Walk In Closet
56 Wine Cellar
57 Workshop
M28705
1
AUXILIARY
LOCKOUT
BALANCE
POINT **
M28706