Pull the drain hose out from top to proceed with
installation
Hose
Installation Instructions
15
CONNECT TO DRAIN
5
The drain or standpipe must be capable of accepting a
discharge at a rate of 16 gal per minute. The drain height
must be 30" minimum and 96" maximum.
The standpipe diameter must be 1-1/2" minimum.
There MUST be an air gap around the drain hose in the
stand pipe. A snug fit can cause a siphoning action.
For a drain facility less than 33" high, the hose, coupling
and clamps provided in the machine must be used and,
in addition, a siphon break MUST be installed on the back
of the machine. Obtain and use a siphon break kit and
follow the instructions in the kit.
If water valves and drain are built into wall, fasten drain
hose to one of water hoses with cable tie provided
(ribbed side on inside). If your drains is a standpipe,
fasten drain hose to standpipe with cable tie provided.
Drain
hose
5" Max.
insertion
into
drain
30"
Min.
Cable
tie
Standpipe
NOTE: Placing the drain hose too far down the drain pipe
can cause a siphoning action. No more than 5" of
hose should be in the drain pipe. There must be an
air gap around the drain hose. A snug fit can also
cause a siphoning action.
Wall
Drain
Cable
hose
5" Max.
insertion
into
30"
drain
Min.
tie