For installer
Menu
Installer setup System setup
Optional PCB connectivity
1
To connect to the external PCB
required for servicing.
• If the external PCB is connected (optional), the system will have following additional functions:
Buffer tank connection and control over its function and temperature.
1
Control over 2 zones (including the swimming pool and the function to heat water in it).
2
Solar function (the solar thermal panels connected to either the DHW (Domestic Hot Water) Tank or the Buffer Tank.
3
External compressor switch.
4
External error signal.
5
SG ready control.
6
Demand control.
7
Heat-Cool SW
8
Zone & Sensor
2
To select the sensors and to
select either 1 zone or 2 zone
system.
Heater capacity
3
To reduce the heater power if
unnecessary.*
3 kW / 6 kW / 9 kW
* Options of kW vary depending
on the model.
Anti freezing
4
To activate or deactivate the
water freeze prevention when
the system is OFF
5
Tank connection
To connect tank to the system.
6
Buffer tank connection
To connect tank to the system
and if selected YES, to set
T temperature.
• The optional PCB connectivity
must be selected YES to
enable the function.
• If the optional PCB connectivity
is not selected, the function will
not appear on the display.
14
Default Setting
Setting Options / Display
No
Zone
• After selecting 1 or 2 zone system, proceed to
the selection of room or swimming pool.
• If the swimming pool is selected, the
temperature must be selected for
T temperature between 2 °C ~10 °C.
Sensor
* For room thermostat, there is a further
selection of external or internal.
3 kW
Yes
No
No
Yes
5 °C
Set T for Buffer Tank