Please make sure that you don't have any overlapping channels in order to control each TS-155/TS-255
correctly and independently from any other fixture on the DMX data link. If two, three or more TS-155/TS-255
are addressed similarly, they will work similarly.
Occupation of the DIP-switches:
Setting the DMX-
starting address:
Projector number
& channels
Device 1 - channels 1-6
Device 2 - channels 7-12
Device 3 - channels 13-18
Device 4 - channels 19-24
Device 5 - channels 25-30
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the effect to the mains, the TS-155/TS-255 starts running. During the Reset, the motors
are trimmed and the device is ready for use within approximately 20 seconds.
Turn the objective-lens for adjusting the focus in order to obtain a sharp projection.
Stand Alone operation
In the Stand Alone mode, the TS-155/TS-255 can be used without controller. You can do without a controller
as the TS-155/TS-255 features a built-in microphone, which provides automatic sound control.
Disconnect the TS-155/TS-255 from the controller and set all DIP-switches to Off.