Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the effect to the mains, the TB-250 starts running. During the Reset, the motors are
trimmed and the device is ready for use within approximately 20 seconds.
Turn the objective-lens for adjusting the focus in order to obtain a sharp projection.
Stand Alone operation
In the Stand Alone mode, the TB-250 can be used without controller. You can do without a controller as the
TB-250 features a built-in microphone, which provides automatic sound control.
Disconnect the TB-250 from the controller and set all DIP-switches to Off.
Call up the internal program
In order to call up the internal program, set DIP-switches No. 9 and 10 to On.
Master/Slave-operation
Connect the master and slave-devices as desribed above and set the DIP-switches accordingly.
Please note: If you wish to change from one operating mode into another, you have to unplug the projector
from the mains and plug it again.
DMX-controlled operation
You can control the projectors individually via your DMX-controller. Every DMX-channel has a different
occupation with different features.
DMX-protocol
Control-channel 1 - Mirrored cylinder movement
Push slider up in order to move the mirrored cylinder.
Gradual mirrored cylinder adjustment from one end of the slider to the other (0-255, 128-center).
The mirrored cylinder can be stopped at any position you wish.
Decimal Hexad. Percentage S/F
0 255
00 FF
0% 100%
International
L
N
F Gradual adjustment of the mirrored cylinder position from left to right
Feature