Start-up:
The device should be cleaned with a damp cloth and suitable detergent. Rinse and dry.
Check the oil level through the sight glass during the first installation unscrew the 4 crankcase screws. Oil
bath model), do so each time the machine is serviced.
Switch on the device using the main switch. To turn off the device, press the main switch.
Choose the vacuum time by pressing the "SET / SEAL" button, when the digits flash, press the + or -
buttons to increase or decrease the values.
To choose the welding time, press the "SET / SEAL" button a second time to memorize the vacuum time
setting and switch to the welding time (the ideal welding time is 3.5 seconds). When the digits are flashing
press the + or - keys to increase or decrease the values.
Press "SET / SEAL" again to store everything.
Position the bag inside the chamber and position the open mouth of the bag perfectly flat on the seal bar.
Use the bars provided to level the product relative to the seal bar.
Lower the bell and exert slight pressure so that it remains closed.
For the automatic version, the bell rises by itself after the complete cycle.
NOTE ! The small red diode which lights up when setting the times, symbolizes half-seconds.
Light switch
main
Cycle start
Vacuum display
in %
The sachets should not be filled more than 50%.
Remove the lower radii to create a drop from the seal bar.
Tout le matériel CHR disponible sur notre site en cliquant ICI ou sur le logo et profitez des meilleurs offres et des meilleurs garanties
Tél: 09 71 04 20 23
Cliquez ici pour découvrir tout nos produits CHR
Cliquez ici pour le catalogue produits Casselin
Display welding
time in seconds
Email: info@stock-direct-chr.com
Modification of
empty or weld time
+ Increase
- Decrease
Values
EN