6.9 Stop adjustment
1
Fig.13
6.10 Electrical connections
All devices, supply included, must be installed up to standard and in compliance with the regulations in force. Separate the
power cables from the control cables, above all if the paths are long (over 50m). As to the cable section (aerial excluded), TAU
recommends: supply 1.5mm², other cables 0.5mm², follow anyway IEC 364 and the installation regulations in force in your
country. To access the control card, remove the cabinet cover after removing the locking screws and washers. It is then possi-
ble to reach the connections.
Note: internal connections are already made and tested. The supply, external photocell, LEDs and any remote con-
trols must be connected and the card must be programmed.
6.11 Last operations
When the correct operation of all devices controlling the bar has been checked, make sure everything is reset before handing
over to the users. Place signs warning people about the barrier where they can be easily read.
7. USE
The barrier has been exclusively designed to limit the flow of vehicles and/or persons in restricted entrances by means of a bar.
In the event of blackout, functioning can be guaranteed by means of an optional 12V dry battery.
Furthermore, it also comprises electrical equipment and therefore must be approached and used with caution and foresight.
In particular we recommend:
• not to touch the equipment with wet hands and/or bare or wet feet;
The barrier is normally supplied with the stops already adjusted
for perfect travel.
If the plate has not been cemented properly, the bar might not be
perfectly horizontal or vertical and the installation might not be
successful from an aesthetic point of view.
To correct the vertical position (=opening), close the bar, open
the door and rotate the free screw (1 pic. 13) in a clockwise (to
increase the bar travel) or anticlockwise direction (to reduce the
bar travel).
2
Similarly, to correct the horizontal position (=closing), open the
bar and adjust the free screw (2 pic. 13).
After checking and adjusting the bar opening and closing opera-
tion, tighten the locknuts under the screws.
Whenever the position of the mechanical stops is modi-
fied, the saving procedure on the control card must be
performed (see K206MA instructions).
When adjustment has been completed, carry out the saving
procedure onto the control card (see K206MA instructions),
checking the correct position of the bar from the second au-
tomatic operation (the first is used by the control unit to ac-
cept the new stops); repeat the procedure as required.
When all the mechanical and electronic installation is complete,
fix the cabinet cover, reposition the door and lock.