Descargar Imprimir esta página

StetSom EXPORT LINE EX6000 Manual De Usuario página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

Diagnost Guide
In the eventuality of any problems, the amplifi er will power down and the RED LED (PROT) light will begin to blink.
Depending on the problem, the RED LED (PROT) light will fl ash a certain number of ti mes. The following table summarizes
the diagnosti cs:
Number of Flashes
1
2
3
4
NOTE: In the event that the RED LED (PROT) light is fl ashing conti nuously, unplug the speakers and turn the
equipment back on. If the problem persists, contact STETSOM tech support.
Technical Specifi cati ons
Channels:
Power @ 14.4V - 1 Ohm (RMS):
Power @ 14.4V - 2 Ohms (RMS):
Power @ 14.4V - 4 Ohms (RMS):
Min. Output Impedance:
Input Impedance:
Input Sensiti vity:
T.H.D:
Signal to Noise Rati o:
Freq. Resp. (-3dB) @ 1 Ohm:
Crossover Low Pass:
Crossover High Pass:
EQ - BASS @ 45Hz:
EQ - MID BASS @ 270 Hz:
EQ - MID HIGH @ 2KHz:
Over Clip (Power):
Power Supply:
Consumpti on Music:
Consumpti on BASS:
Dimensions (H x W x L):
Weight:
The measured data are based on equipment from the STETSOM laboratory. Frequency reference of 1Khz with THD+N to ≤10%
in impedances referring to the indicated in each measurement. The electronic components and the manufacturing process can
present manufacturing variati ons, thus leading to a variati on in the measurements made.
Any updates made in this manual will be available for consumers to consult without any charge on the brand's site.
It is recommended that the updated manual be consulted whenever necessary.
EU Declarati on of Conformity (DoC):
EU Declarati on of Conformity (DoC):
EX6000EQ - 1 OHM:
EX6000EQ - 2 OHMS:
Problem
Output short circuit
or overload.
Overheati ng.
LOW
Low batt ery.
BAT
Batt ery overload or volta-
OVER
BAT
ge greater than allowed.
www.stetsom.com.br/certi fi cati ons/EX6000EQ_1--EUDoC2014-30-EU.pdf
www.stetsom.com.br/certi fi cati ons/EX6000EQ_2--EUDoC2014-30-EU.pdf
Check to make sure the speaker cables are
pro-perly isolated.
Verify minimum impedance.
Make sure the equipment is installed in a
well venti lated locati on.
When used for long periods, the batt ery will
run down. Recharge the batt ery.
Have the batt ery and/or alternator checked
by a professional.
EX6000EQ 1 OHM
1
6700W
4131W
1 OHM
25K OHMS
0.2V
≤ 10% THD
>90dB
10Hz ~ 15KHz
50Hz ~ 15KHz
10Hz ~ 700Hz
±10dB
±10dB
±10dB
15%
9.5 ~ 15Vdc
3.8 ~ 295A
3.8 ~ 590A
77 x 294 x 375 mm
5.0 Kg
Soluti on
EX6000EQ 2 OHMS
1
6380W
3660W
2 OHMS
25K OHMS
0.2V
≤ 10% THD
>90dB
10Hz ~ 15KHz
50Hz ~ 15KHz
10Hz ~ 700Hz
±10dB
±10dB
±10dB
15%
9.5 ~ 15Vdc
3.3 ~ 290;A
3.3 ~ 580A
77 x 294 x 375 mm
5.0 Kg
9

Publicidad

loading