2. Range of humidity: 20%-99%.
3. Tendency of temperature change: one check per hour, compared to previous data. If the
temperature changes more than 1ºC the arrow will be flat.
Pressure and Weather Forecast:
1. Turn on power to set the height, or it will be 0.
2. Two kind of pressure units: Hpa/Mb or in Hg
3. Records the pressure data of the past 12 hours.
4. Compares the pressure data with the previous data every 60 minutes. If the change is more than
2 hpa the pressure arrow will change.
5. Checks data every hour and will display the weather graphics according to the result.
RCC Reception Mode:
1. RCC reception format: DCF, the reception time is about 10 minutes.
2. RCC reception way.
3. It will begin to receive the RCC 3 minutes after turning on the unit.
4. RCC reception graphic:
The tower graphic flashes when receiving, the tower graphic will also flash when lost or no signal. The
tower graphic will not flash when synchronizing the signal, but the arc-shaped antenna symbol on top
of the tower graphic is flashing. The whole RCC reception graphic will display when the reception is
successful: The tower graphic will turn off and exit RCC when the signal reception fails.
Part II
There are 5 buttons at the rear: RST, UP, DOWN, HISTROY, ALERT. These buttons are used for the
following functions:
1. ALERT Button
* While in normal display mode, press this button to activate or deactivate the temperature alert
function. An arrow icon will appear to indicate the funcion has been activated, or the arrow icon will
disappear to indicate the alarm is deactivated.
* While in normal display mode, press and hold this button for 3 seconds to enter the temperature
alert settings. The door temperature digits will start flashes. Press the ALERT button at the rear to
set the temperature (0°C-50°C) at which the statio nhas to sound an alarm.
2. UP Button (at the rear)
* In normal display mode press this button to select pressure unit between Hpa /Mb or Hg.
* In normal display mode press and hold this button for 3 seconds to enter weather forecast display
mode, select by pressing the DOWN button (at the rear) among sunny, cloudy, rainy, etc.
3. DOWN button (at the rear)
* In normal display mode press this button to toggle between degrees Celsius or Fahrenheit.
4. HISTORY Button
* Press this button repeatedly to show the history record of the barometer of the past 12 hours. The
hour is displayed in the bottom right corner of the barometer chart.
* In normal display mode press this button to check the barometer history of 12 the past hours.
* In normal display mode press and hold this button for 3 seconds to enter sea level setting.
5. RESET
Press this button to reset all functions.