10
Technical data
Sensing range min.
Sensing range
Sensing range max.
Light spot size / distance
Supply voltage U
B
Output current I
max.
Switching frequency
Response time
Enclosure rating
Protection class
Circuit protection
Ambient temperature, operation
Object with 90% remission factor (complies with standard white according to DIN 5033)
1)
2)
Limit values
Reverse polarity protected U
B
Residual ripple max. 5 V
ss
3)
With light / dark ratio 1:1
4)
Signal transit time with resistive load
5)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
10.1
Dimensional drawings
Table 5: Dimensional drawings
13.6
(0.54)
M18x1
1
2
Figure 5: ZTx18-1xxxxx / ZTx18-Axxxxx
8021944.1HW1 /2022-11-14 | SICK
Subject to change without notice
connections
2 x Ø 3.5 (0.14)
3
4
14.1
(0.56)
23
(0.91)
OPERATING INSTRUCTION
ZTB18-xxxxxxD02
5 mm
50 mm
50 mm
1)
8 mm / 100 mm
DC 10 ... 30 V
2)
≤ 100 mA
500 Hz
3)
≤ 1 ms
4)
IP67
III
A, B, D
5)
–40 °C ... +55 °C
13.6
(0.54)
1
2
Figure 6: ZTx18-2xxxxx / ZTx18-Bxxxxx, cable
O P E R A T I N G I N S T R U C T I O N | ZTB18
ZTB18-xxxxxxD04
5 mm
100 mm
100 mm
1)
8 mm / 100 mm
DC 10 ... 30 V
2)
≤ 100 mA
500 Hz
3)
≤ 1 ms
4)
IP67
III
A, B, D
5)
–40 °C ... +55 °C
2 x Ø 3.5 (0.14)
M18x1
3
14.1
4
(0.56)
21.9
(0.86)
en