FUNCTIONS & DISPLAY:
1. There are 4 stages of battery capacity gauge on LCD.
2. When pressing VSR switch, then the illuminative LED will be on at the same time.
3. There are 5 stages of torque clutches and one "MAX" stage.
REFERENCE TORQUE VALUES OF EACH TORQUE CLUTCH STAGE
Stage 1: average value: 15 ft/lbs (20 Nm)
Stage 2: average value: 22 ft/lbs (30 Nm)
Stage 3: average value: 33 ft/lbs (45 Nm)
Stage 4: average value: 41 ft/lbs (55 Nm)
Stage 5: average value: 52 ft/lbs (70 Nm)
Max. Torque value: 80 ft-lbs (110 Nm)
NOTE
Please note these values are lab. test value for reference only. Accuracy varies
due to bolt size, grade, and various other factors.
LED INDICATING LAMP SIGNAL & MESSAGE ON LCD DURING
OPERATION:
1. During Operation: LCD will show the setting stage of digital clutch.
2. Designated Torque Reached: LED indicating lamp will stay on in green and LCD
will show the setting stage of digital clutch.
3. When the battery voltage is under 14.4 V, the power will be cut-off. At the same
time, LED indicating lamp will be on in red and LCD panel will show "LV".
4. When the temperature over 140 F (60 C), the power will be cut-off. At the same
time, LED indicating lamp will be on in red and LCD panel will show "OT".
MEMORY FUNCTIONS:
Certain work environments requires a constant working torque range. The memory
function will hold the selected torque setting until it has been adjusted.
NOTE
Always check the direction of the rotation before use.
1English1
OPERATION
Low Voltage
English
Over Temperature