Symptoms
Heater doesn't
ignite
The fuel in-
dicator lamp
doesn't work
Power loss
Abnormal com-
bustion
Unpleasant
smells
Fuel leakage
AUTOMATIC DEACTIVATION
This heater is fitted with a safety system that ensures that it switches off
automatically after 36 hours continuous operation. If desired, you can switch the
heater on again by pressing the ON/OFF button
I
CHILDPROOF LOCK
The childproof lock can be used to prevent children accidentally changing the
O
heater settings. When the heater is burning and the childproof lock is on, the heater
can only be switched off. Other functions are blocked then. If the heater has already
been switched off, the childproof lock also prevents accidental ignition of the
heater. Activate the childproof lock by pressing the CHILDLOCK key O and holding it
down for more than 3 seconds. The childlock indicator will appear on the information
display (Fig. O), indicating that the childproof lock has been activated. Switch off the
childproof lock by pressing the CHILDLOCK key O and holding it down for more than
3 seconds once again.
J
THE 'OIL' INDICATOR
If the low fuel level indicator lights up in combination with a short tone, then
the fuel tank is empty. The heater will automatically burn at its lowest setting
for a period of about 80 minutes. The fuel tank must be replenished.
4
134
134
Causes
The child safety catch lights
up
The tank is empty
The tank is deformed
Dirt particles dust or water on
the filter and / or in the fixed
tank
The fuel indicator flashes
The fuel indicator flashes
A poor quality fuel has been
used.
A poor quality fuel has been
used.
Poor ventilation
Dust on the ventilator filter
A poor quality fuel has been
used
No fuel in the tank
Fuel leakage or spilled fuel
Move the heater, the tank is
not empty
A poor quality fuel has been
used.
Measures to be taken
Turn the child safety catch off
Fill the tank
Replace the tank
Clean the fixed tank and the
fuel filter.
Fill the tank
Remove the fuel from the
two tanks, then rinse with the
correct fuel.
Ventilate regularly
Clean the ventilator filter
Remove the fuel from the
two tanks, then rinse with the
correct fuel.
Fill the tank
Do not use any more and
contact your dealer
(see section D).
20
20

Publicidad

loading

Este manual también es adecuado para:

Sre 1730 tc-2