To use hot water again after stop, do not let the hot water splash you, because the water
temperature in the unit might be very high. Use it after several seconds of hot water outflow
to avoid scald.
4.3 Stop To Use
Close the water outlet valve, the unit will stop automatically.
①
②
Press the ON/OFF key on the operation panel.
Close the water inlet valve.
③
④
Close the main gas switch.
⑤
Switch off the power switch or pull out the power supply plug.
4.4 Anti-frozen Treatment Of The Unit
●
Ani-frozen water supply method:
Not only the main body, but also the cold/hot water pipes and valves can be protected from freezing.
When there is a line controller, the ON/OFF key of the line controller shall be at the OFF position before
you proceed with the following operations.
①
Close the gas valve.
②
Open the water outlet valve (the water inlet valve is semi-open).
WARNING
Close the gas valve.
water outlet valve
water inlet valve
19
V.1