PTM: Data Storing Device 
The PTM is a tiny circuit board into which the Agility panel can transmit a copy of the systemʹs configuration. The PTM stores this copy 
and can also transmit the configuration information back to the Agility panel. 
 
To transfer the system configuration from the panel to the 
PTM, follow this procedure: 
1.  Disconnect the flat cable and remove the Agility main unit 
from its wall bracket. 
Note: Make sure the battery is inserted into the main unit. 
2.  Make sure that Dipswitch 2 is set to OFF (default setting). 
3.  Place the PTM onto the 5‐pin PTM connector located on the 
rear of the main unit PCB. The PTM LED will turn on. 
4.  Press the main unit button for 5 seconds. The PTM LED 
will begin to flash during the transmission of information 
to the PTM. 
5.  Once transmission is complete, the panel will sound a 
confirmation beep and the PTM LED will stop flashing and 
turn on steady.  
6.  Disconnect the PTM from the main unit. 
7.  Reconnect the flat cable to the main unit and replace the 
main unit in its wall bracket. 
ITALIANO
PTM: Dispositivo di Trasferimento Programmazione 
Il PTM è una piccola scheda elettronica che permette alla centrale Agility di trasmetterle una copia della configurazione del sistema. Il 
PTM conserva questa copia e può inoltre ritrasmettere le informazioni alla centrale Agility. 
 
Per  trasferire  la  configurazione  del  sistema  dal  PTM  alla 
centrale, seguire i seguenti passaggi: 
1.    Scollegare  il    cavo  piatto e  rimuovere  l'unità  principale  di  
Agility dal supporto a parete. 
Nota: assicurarsi che la batteria sia inserita nell'unità principale. 
2. Assicurarsi che il microinterruttore 2 sia su OFF 
(impostazione predefinita). 
3.  Posizionare il PTM sull'innesto a 5 aghi nominato PTM 
collocato sul retro dell'unità centrale PCB. Il LED PTM  si 
accende. 
4.  Premere il tasto dell'unità principale per 5 secondi. Il LED 
PTM lampeggia velocemente durante la trasmissione delle 
informazioni al PTM. 
5.  Una volta che la trasmissione è stata completata, la centrale 
emette un avviso sonoro e il LED PTM smette di 
lampeggiare e si accende con luce fissa.  
6.  Rimuovere il modulo PTM dall'unità centrale. 
7.  Ricollegare il cavo piatto all'unità centrale e ricollocare 
lʹunità centrale nel suo supporto a parete. 
PTM
(Program Transfer Module)
 
To transfer the system configuration from the PTM to the Agility 
panel, follow this procedure: 
1.  Disconnect the flat cable and remove the Agility main unit from its 
wall bracket. 
Note: Make sure the battery is inserted into the main unit. 
           Make sure that the Default Enable system flag is on. 
2.  Set Dipswitch 2 to ON. 
3.  Place the PTM onto the 5‐pin PTM connector located on the main 
unit PCB. 
4.  All LEDS on the main unit will begin to flash simultaneously. The 
PTM LED will begin to flash during the transmission of 
information to the panel. 
5.  Once transmission is complete, the panel will sound a confirmation 
beep. 
Note: If the procedure fails the panel will make 3 short error beeps, and you 
will need to do the procedure again 
6.  Disconnect the PTM from the main unit. 
7.  Reset Dipswitch 2 to OFF. 
8.  Reconnect the flat cable to the main unit and replace the main unit 
in its wall bracket. 
Per trasferire la programmazione dal PTM ad Agility, seguire questi 
passaggi: 
1.  Scollegare il  cavo piatto e rimuovere l'unità principale di  Agility 
dal supporto a parete. 
Note: assicurarsi che la batteria sia inserita nell'unità principale.  
Assicurarsi che nel menù Sistema, Controlli, Base, la voce "Abilita   
Default" sia posta su SI. 
2.  Spostare il microinterruttore 2 su ON. 
3.  Posizionare il PTM sull'innesto a 5 aghi collocato sul retro 
dell'unità centrale PCB. 
4.  Tutti i  LED dell'unità centrale lampeggiano simultaneamente. Il 
LED PTM lampeggia velocemente durante la trasmissione 
dell'informazione alla centrale. 
5.  Una volta completata la trasmissione, la centrale emette un tono di 
conferma. 
Nota: se la procedura non andrà a buon fine la centrale emetterà 3 brevi 
segnali acustici e la procedura dovrà essere ripetuta. 
6.  Rimuovere il modulo PTM dall'unità centrale. 
7.  Riportare il microinterruttore 2 su OFF. 
8.  Ricollegare il cavo piatto all'unità centrale e ricollocare lʹunità 
centrale nel suo supporto a parete. 

Publicidad

loading

Resumen de contenidos para RISCO Group Agility PTM

  • Página 1 (Program Transfer Module)   ENGLISH   PTM: Data Storing Device  The PTM is a tiny circuit board into which the Agility panel can transmit a copy of the systemʹs configuration. The PTM stores this copy  and can also transmit the configuration information back to the Agility panel.    To transfer the system configuration from the panel to the  To transfer the system configuration from the PTM to the Agility  PTM, follow this procedure:  panel, follow this procedure:  1.  Disconnect the flat cable and remove the Agility main unit  1.  Disconnect the flat cable and remove the Agility main unit from its  from its wall bracket.  wall bracket.  Note: Make sure the battery is inserted into the main unit.  Note: Make sure the battery is inserted into the main unit.             Make sure that the Default Enable system flag is on.  2.  Make sure that Dipswitch 2 is set to OFF (default setting).  2.  Set Dipswitch 2 to ON.  3.  Place the PTM onto the 5‐pin PTM connector located on the  3.  Place the PTM onto the 5‐pin PTM connector located on the main  rear of the main unit PCB. The PTM LED will turn on.  unit PCB.  4.  Press the main unit button for 5 seconds. The PTM LED  4.  All LEDS on the main unit will begin to flash simultaneously. The  will begin to flash during the transmission of information  PTM LED will begin to flash during the transmission of  to the PTM.  information to the panel.  5.  Once transmission is complete, the panel will sound a  5.  Once transmission is complete, the panel will sound a confirmation  confirmation beep and the PTM LED will stop flashing and  beep.  turn on steady.   6.  Disconnect the PTM from the main unit.  Note: If the procedure fails the panel will make 3 short error beeps, and you  will need to do the procedure again ...
  • Página 2   FRANÇAIS   PTM: Module de Transfert de Programmation  Le PTM est une carte de circuit imprimé minuscule dans laquelle la centrale Agility peut transmettre une copie de la configuration du  système. Le PTM stocke cette copie et est en mesure de renvoyer les informations de configuration à la centrale Agility. Pour transférer la configuration du système de la centrale  Pour transférer la configuration du PTM vers la centrale Agility,  vers le PTM, suivez cette procédure :  suivez cette procédure :  1.  Déconnectez le câble plat et retirez lʹunité principale de  1.  Déconnectez le câble plat et retirez lʹunité principale de lʹAgility de  lʹAgility de son support mural.  son support mural.  Note : Vérifiez que la batterie est insérée dans lʹunité principale.  Note : vérifiez que la batterie est insérée dans lʹunité principale.  2.  Assurez‐vous que le DIP switch 2 est réglé sur OFF  2.  Réglez le commutateur DIP 2 sur ON.  (paramètre par défaut).  3.  Placez le PTM sur le connecteur PTM à 5 broches situé sur le PCB  de lʹunité principale.  3.  Placez le PTM sur le connecteur PTM à 5 broches situé à  4.  Toutes les LED de lʹunité principale se mettront à clignoter  lʹarrière du PCB de lʹunité principale. La LED du PTM  simultanément. La LED du PTM clignotera rapidement durant la  sʹallumera.  transmission des informations au panneau.  4.  Appuyez pendant 5 secondes sur le bouton de lʹunité  5.  Une fois la transmission terminée, la centrale émettra un bip de  principale. La LED du PTM clignotera rapidement durant  confirmation.  la transmission des informations au PTM.  Note :   si la procédure échoue, la centrale émettra 3 bips dʹerreur brefs et il  5.  Une fois la transmission terminée, la centrale émettra un  sera nécessaire de redémarrer la procédure.  bip de confirmation et la LED du PTM sʹarrêtera de  clignoter et restera allumée de manière stable.   6.  Déconnectez le PTM de lʹunité principale.  6.  Déconnectez le PTM de lʹunité principale.  7.  Remettez le DIP switch 2 sur OFF. ...