Operation
With the hood switched off, pressing any key will activate
the control panel in stand-by mode. The symbols are backlit
by a white light, allowing you view and select the desired
function.
Pressing one of the keys again will start the corresponding
function, and its symbol will light up. After all functions have
been switched off, the control panel will remain in stand-by
mode for around 30 seconds and then switch off automatically.
A: Light ON/OFF key: press this touch sensor to switch
on or off the lights of the hood.
C: Motor ON/OFF key (4 speed): press this touch sensor
to switch on the hood extractor fan at the same speed as it
was when last switched off. Use the „D" and „B" keys to
vary the speed (power) of extraction.
B: Decrease extraction speed (power) key: press this
touch sensor to reduce the extraction speed of the hood.
D: Increase extraction speed (power) key: press this
touch sensor to increase the extraction speed of the hood.
E: Timer key: when this touch sensor is pressed,
independently of the extraction speed selected, the timer
function will be activated. Press once to set the timer for 5
minutes, press a second time for 10 minutes and a third time
for 20 minutes. During this phase, the „E" symbol will flash.
To reset the timer, press the motor key, „C"
F: Reset filters key: press this touch sensor to reset the
signal that warns that the metal grease filter (1) is saturated
and the charcoal filter (2) should be replaced.
(1)
After 40 hours of using the hood, the „F" symbol
will flash to indicate the necessity of cleaning
the metal grease filters.
(2)
After 120 hours of using the hood, the „F" symbol
will light up to indicate the necessity of replacing
the activated charcoal filters.
Sensor function: pressing the „B" and „D" keys at the
same time will activate the sensor. In this mode the extraction
speed sets itself automatically and the „B e D" key flashes
intermittently. To return to manual operation, press either the
„B" or the „D" key.
TSL2
F
E
D
B
C
A
Maintenance
Prior to any maintenance operation ensure that the cooker hood
is disconnected from the electrical outlet.
C l e a n i n g
The hood must be cleaned frequently both inside (apart from
the area behind the grease filter) and outside. Use a cloth
moistened with denatured alcohol or neutral liquid detergents.
Never use products containing abrasives.
Warning:
Failure to carry out the basic standards of the
cleaning of the cooker hood and replacement of the filters may
cause fire risks. Therefore we recommend observing these
instructions.
Anti-grease Filter:
must be cleaned once a month, with non abrasive detergents, by
hand or in dishwasher on low temperature and short cycle.
When washed in a dishwasher, the grease filter may discolour
slightly, but this does not affect its filtering capacity.
Charcoal Filter - (only for filter version)
The active charcoal filters F are not washable nor regenerative.
It should be changed every 6 months in normal use.
The active charcoal filters capture unpleasant cooking odours.
Replacing lightbulbs
Warning! Prior to touching the light bulbs ensure they are cooled
d o w n .
Open the light cover by pressing with a finger the part marked
„ p u s h " .
Replace the dead bulb.
Use only a halogen bulb of 20W max (G4), taking care not to
touch it with naked hands.
Close the light cover.
Led Light
If the lighting group LED does not work, please contact the
technical service center in order to replace the whole group