you have read, understand and are following all information provided in the
Important Safety Information section of this manual. Failure to follow those
instructions can cause death, serious injury or property damage.
Prior to each gas fireplace operation, check the hose and valve for evidence
of excessive abrasion or wear though the visual check hole on the side of the
base. Replace visual check cap prior to operating fireplace.
BURNER CONNECTIONS
Make sure the regulator valve and hose connections are securely fastened
to the burner and the tank. If your unit was assembled for you, visually check
the connection between the burner pipe and orifice. Make sure the burner
pipe fits over the orifice.
!
WARNING
Failure to inspect this connection or follow
these instructions could cause a fire or an explosion, which can
cause death, serious bodily injury, or damage to property
Please refer to diagram for proper installation.
If the burner pipe does not rest flush to the orifice please
contact Ocean Rock USA at 800-678-7294 for assistance.
CHECKING FOR LEAKS
Make a leak check solution by mixing 1 part dish
washing soap with 3 parts water in a spray bottle.
Make sure control knob is "OFF." Then, turn LP gas
tank to "ON" at valve.
Spray leak solution on valve connections paying
particular attention to the areas indicated by arrows.
If any bubbles appear turn LP gas tank OFF, reconnect
and re-test. If you continue to see bubbles after several
attempts, disconnect LP gas source and contact
Ocean Rock USA at 800-678-7294 for assistance.
If no bubbles appear after one minute turn tank OFF,
wipe away solution and proceed.
PRE-USE INSTRUCTIONS
WARNING
Before using this outdoor fire table, make sure
12 / 20
Orifice is located
in this connection
Check for leaks at these locations
Expanded View