1 ] Run house power cable between service panel and hood location. Run the house power
2 ] Hang hood from (4) mounting screws previously installed. Slide hood back towards wall until
18
Install the Hood (Standard installation)
cable into the hood through the strain relief previously installed in step 6 on page 10.
mounting screw heads are engaged in narrow end of keyhole slots in top of hood. Tighten
screws securely. Attach power cable to the hood using the strain relief.
3 ] Connect ductwork to hood and use metal foil duct tape to make joints secure and air-tight.
Make sure the damper assembly (or round duct plate) enters the ductwork and that the
damper opens and closes freely.
DUCTED INSTALLATION ONLY