Descargar Imprimir esta página

Lotus CWT-64G Guia Para La Intalación E Instrucciones De Uso página 23

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

The only operation necessary is the substitution of the nozzle according to the type of gas.
It is therefore necessary to unscrew the screws as specified in the previous point; with a suitable spanner unscrew the
fitting and substitute the nozzle with a suitable one. With the right nozzle, the flame must lap the thermocouple.
Important!
After having carried out the conversion to another type of gas, it is necessary to update the data plate, indicating the
type of gas for which the appliance has been converted.
The appliance contains the instructions necessary for use.
Check the appliances for gas leaks.
Examine the flame of the pilot burner; it must lap the thermocouple and be blue, otherwise examine the nozzle of
the pilot burner.
Check the lighting and flame of the main burner.
We urge the user to follow the instructions when using the appliance.
With prolonged use of the appliance, it is essential to carry out regular maintenance for the safe functioning of the
appliance; we therefore recommend drawing up a contract for after sales service.
Maintenance must be done only by specialized personnel, observing the norms in force and our indications.
It is possible to substitute parts such as: gas cock, piezoelectric device or gas piping in a very simple way. To substitute
the parts, proceed as follows:
Cock: after taking off the front panel, unscrew the screwed fittings from the gas connections and the thermocouple
fitting, after which, substitute the cock.
To substitute the thermocouple, unscrew the fitting of the pilot burner, likewise unscrew the thermocouple fitting
and substitute the element.
The spark plug must be unscrewed and substituted.
Attention! In the event that smoke is given off when the appliance is started up, it is necessary to leave the appliance on
without being used for approximately an hour or until the smell disappears.
LIGHTING AND ADJUSTING THE MAIN BURNER
On the front panel, above each knob, the burner it corresponds to is indicated by the index
To light, turn the knob to the left from position "0" to the
keep it pushed down and press the button with the
Keep the knob pressed a few second and then let it go, this lights the pilot.
If the flame goes out you have to repeat the procedure.
By turning the knob round to the
By turning the knob round to the
Turning off the appliance
Push and turn the knob into position "0". This command blocks the gas supply to both the main burner and the pilot
burner. To relight the appliance, it is necessary to turn the knob again into position * and press the button.
The drip pan must be checked regularly and emptied before getting full. In any event, the pan must be cleaned after
switching off the appliance.
INSTRUCTIONS FOR DISCHARGING GAS EMISSIONS
Type "A" Appliances (See data plate)
Type "A" appliances must discharge the products of combustion into extractor hoods or similar devices connected to
and efficient chimney, or directly outside. (Natural Discharge) Fig.1.
GB
CHECKING FUNCTIONING
MAINTENANCE
SPARE PARTS
INSTRUCTIONS FOR USE
To switch off, move the knob back into position " 0".
IE
IT
CH
position the burner is at maximum
position the burner is at minimum.
DRIP PAN
23
symbol (see figure);
symbol until the gas lights

Publicidad

loading

Este manual también es adecuado para:

Cwt-66gCwt-68g