THERMOSTAT INSTALLATION
Follow the instructions included with the thermostat.
Locate the thermostat approximately five feet above the
floor. Always mount the thermostat on an inside wall
where it won't be affected by heat or cold sources such
as direct sunlight, televisions, fireplaces, hidden hot or
cold water pipe, drafts, etc. The thermostat must never
be installed in an adjoining room where a door can be
closed between the thermostat and floor furnace. This
floor furnace is equipped with a self-generating control
system. Never connect to a 24-volt transformer or to the
household electric system. Do not use more thermostat
wire than is included with the floor furnace.
FIGURE 12
Terminal Block On Gas Valve
Thermostat
Wire Nut
WIRE AS INDICATED: Figure 12
STEP 1 Connect black limit switch wire to black
thermostat wire using wire nut. (Nut not
furnished).
STEP 2 Connect white thermostat wire to terminal on
gas valve marked "TH TP".
STEP 3 Connect white limit switch wire to terminal on
gas valve marked "TH".
STEP 4 Connect the thermostat wires to the thermostat
following the instructions provided by the
thermostat manufacturer.
Limit Switch Wires
Powerpile
Generator
Thermostat
Limit
Switches
Red
Powerpile
Generator
TH
TP
TH
TP
TH
TP
TH
TP
Terminal Block
GAS FIRED VENTED FLOOR FURNACES