Fitting/changing batteries

n.B.: When replacing batteries, change all the batteries in the particular unit.
Precision boring head
 unscrew the battery cover (WAF 5)
A
 Carefully raise  the contact tag
B
Change the batteries 
2× 1.55 V. e.g. V76PX or SR1154 
(check correct polarity)
 Carefully press the contact tag back down
C
When  screwing  down  the  battery  cover, 
check that the O-ring is seated correctly.

Display unit

• Remove clip 
2
• Remove rubber sleeve 
• unscrew the battery compartment
• Fitting/changing batteries
  2× AAA 1.5 V (check correct polarity)
• Screw the battery compartment back on, 
slide on the rubber sleeve and clip
adjustment key
• Place the connection side of the adjust-
ment key onto a level supporting surface 
and then press the sleeve downwards.
• Remove sleeve 
2
28
3
2
A
B
C
2
3
• Fitting/changing batteries
  4× AAA 1.5 V (check correct polarity)
• Refit the sleeve, so that the markings 
 (arrow and dot) are in line.
7
7
Markings arrow/dot