Self-Purge Method - Refco ENVIRO-DUO Manual De Instrucciones

Estación de recuperación de dos pistones
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

English

9. Self-Purge Method

①Do not turn off the power when the "complete" light
1.
turns green and unit stops running, please hit the reset
button first, then turn the switch to position "3" to start
purge.
② If the ultimate vacuum meets your request but the
unit is still running, please turn the switch to position
"3" to start purge directly.
2.
When the required vacuum is reached, purging ends.
a.
Close the valve on the refrigerant tank.
b.
Close the check valves on the connecting hoses.
c .
Close the liquid valve and gas valve on the manifold
gauge.
d.
Close the connecting valve between the refrigeration
system and the manifold valve.
e.
Turn the power off, and disconnect all the external
hoses.
f.
Cap the intake port and the outlet port.
17
Instruction Manual ENVIRO-DUO

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

4686353

Tabla de contenido