Descargar Imprimir esta página

U.S. Products King Cobra 310 Información E Instrucciones De Uso página 11

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING:
IF THIS OCCURS
NO SPRAY
PUMP DOES NOT RUN
LOW SUCTION
NO SUCTION
LOW HEAT
NO HEAT
TECHNICAL SPECIFICATIONS
Roto-molded Body:
Vacuum:
VAC Shutoff:
Pump:
Heat:
Capacity:
Cords:
Size:
Wheels:
Hoses:
4/10
CHECK THIS
Holding Tank is empty, or fi lter is plugged.
Clogged spray tip(s).
Pump not running or not primed.
Valve on wand not operating.
Solution hose not completely connected to hose or to machine.
This pump motor runs on AC voltage, so it should start running as soon as you turn on the switch. If the pump
motor does not start running, check the wiring to the switch and to the motor. Check the switch to see if it is "open".
Debris is plugging cleaning tool or vacuum hose.
Drain hose cap is not completely closed.
Recovery tank lid is not seated or gasket is damaged.
Ball in the fl oat is blocking air fl ow. Turn off the vacuum so the ball will drop down, or the recovery tank is full and
needs to be emptied.
No power to motor(s).
Test the switches.
Test the vacuum motors.
Spraying too long. Try spraying for 12-15 seconds, or about three strokes.
Heat exchanger needs to be fl ushed.
Wrong tool being used. Too much water passing through. Longer hose or larger diameter hose, than standard.
Heat is not turned on. The green circuit indicator light must be on.
No power in the wall outlet - check to see if the breaker has tripped.
Call your distributor for additional help.
Lifetime Warranty
7.2" 3-stage, 140" of water lift
Ball Float
Positive displacement, selectable pressure setting
2000 Watts, up to 212 °F
16 gallon Holding Tank; 14 gallon recovery tank
Two, detachable 12/3, hospital grade plugs
39" H X 21" W X 36" L
10", locking, non-marking
25 ft hoses on a reel (patent pending)
INSTRUCTIONS FOR USE
56041963 - KING COBRA
ENGLISH - A
310
®
A-11

Publicidad

loading

Este manual también es adecuado para:

Kc-310