Descargar Imprimir esta página

Black and Decker BM903650RB Manual Del Operador página 18

Publicidad

Idiomas disponibles

Idiomas disponibles

 Mix fuel stabilizer and gasoline prior to filling the tank
by using a gas can or other approved fuel container and
shaking gently to combine.
NOTE: To control the amount of fuel stabilizer being added
to the engine, always mix fuel stabilizer with gasoline
before fueling the tank rather than adding fuel stabilizer
directly into the generator's fuel tank.
 Replace and secure the fuel tank cap.
 Start and run the engine for at least 5 minutes to allow
stabilizer to treat the entire fuel system.
OXYGENATED FUELS
DO NOT USE E15 OR E85 FUEL IN THIS UNIT. IT IS A
VIOLATION OF FEDERAL LAW AND WILL DAMAGE THE
UNIT AND VOID YOUR WARRANTY.
NOTE: Fuel system damage or performance problems
resulting from the use of an oxygenated fuel containing
more than the percentage of oxygenates stated below are
not covered under warranty.
Ethanol. Gasoline containing up to 10% ethanol by volume
(commonly referred to as E10) is acceptable. E15 and E85
are not.
CHECKING/ADDING FUEL
See Figure 8.
WARNING:
Gasoline and its vapors are highly flammable and ex-
plosive. To prevent serious personal injury and property
damage, handle gasoline with care. Keep away from igni-
tion sources, handle outdoors only, do not smoke while
adding fuel, and wipe up spills immediately.
When adding gas to the generator, make sure the unit is
sitting on a flat, level surface. If the engine is hot, let the
generator cool before adding gas. ALWAYS fill the fuel tank
outdoors with the machine turned off.
 Remove the fuel cap.
 Fill the fuel tank to 1 in. below the top of the fuel neck.
 Replace and secure the fuel cap.
NOTE: Always use unleaded gasoline with a pump octane
rating of 86 or higher. Never use old, stale, or contaminated
gasoline, and do not use an oil/gas mixture. Do not allow
dirt or water into the fuel tank.
OPERATION
CAUTION:
On a level surface with the engine off, check the lubricant
level before each use of the generator.
STARTING THE ENGINE
See Figures 9 - 11.
NOTE: If location of generator is not level, the unit may not
start or may shut down during operation.
 Unplug all loads from the generator.
 Turn the fuel valve to the ON position.
 Move the choke lever left to the START position.
NOTE: If engine is warm or the temperature is above
50˚F, move the choke lever right to the RUN position.
 Put the engine switch in the ON ( I ) position.
 Pull the recoil starting grip until the engine runs (a maxi-
mum of 6 times).
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place.
 Allow the engine to run for 30 seconds, then move the
choke lever right to the RUN position.
STOPPING THE ENGINE
See Figures 10 and 12.
To stop the engine under normal operating conditions:
 Remove any load from the generator.
 Turn the fuel valve to the OFF position.
 Put the engine switch in the OFF position.
To stop the engine in an emergency situation:
 Put the engine switch in the OFF position.
WARNING:
While operating and storing, keep at least 3 feet of clear-
ance on all sides of this product, including overhead.
Allow a minimum of 30 minutes of "cool down" time be-
fore storage. Heat created by muffler and exhaust gases
may be hot enough to cause serious burns and/or ignite
combustible objects.
UNDERSTANDING THE DIGITAL DISPLAY
See Figure 13.
The digital display shows AC voltage output, frequency, how
long the engine has been running during the current usage
period, and the total number of hours the unit has been used.
Page 14 — English

Publicidad

loading