Installation
4-wire system
F
A
B
C
A. External ground connector
B. Neutral grounding wire (white)
C. Center silver-colored terminal block
screw
D. Neutral wire (white or center wire)
E. 3/4" (1.9 cm) UL-listed strain relief
F. Neutral wire (white or center wire)
CAUTION
Before Installing the Dryer, confirm 240V is present between L1 and L2 at the power
receptacle. If the Voltage is low, it may not dry properly. Review the "Electrical
requirements" section on page 19 if needed.
WARNING
• All U.S. models are designed for a 3-wire system connection. The dryer frame is
grounded to the neutral conductor at the terminal block. A 4-wire system connection
is required for new or remodeled construction, mobile homes, or if local codes do not
permit grounding through neutral. If you use the 4-wire system, you cannot ground the
dryer frame to the neutral conductor at the terminal block.
26
English
DV3200T_DC68-03784N-00_EN.indd 26
D D
D
L2
L1
E
1. Remove the external ground connector's
screw, and connect the ground wire
(green or unwrapped) of the power cable
to the screw.
CAUTION
• To connect the ground wire to the
neutral position without through
contact A (cabinet ground), contact
a technician. This is not user
serviceable.
• Ring-type terminals are remended. If
using strap terminals, make sure they
are tightened.
2. Loosen or remove the screws from the
center terminal block.
3. Connect the neutral wire (white or
center wire) and ground wire (white) to
the center screw of the terminal block.
Tighten the screw.
4. Connect the other wires to the outer
terminal block screws. Tighten the
screws.
5. Tighten the strain relief screws.
6. Insert the tab of the terminal block cover
into the rear slot of the dryer. Secure the
cover with a hold-down screw.
2020-05-25
11:10:20