SAFETY INFORMATION
Carefully read and follow all safety instructions in this
manual or on pump.
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of the
following signal words and be alert to the potential for
personal injury!
warns about hazards that will cause serious
personal injury, death or major property damage if ignored.
warns about hazards that can cause serious
personal injury, death or major property damage if ignored.
warns about hazards that will or can cause
minor personal injury or property damage if ignored.
The word NOTICE indicates special instructions which are
important but not related to hazards.
DESCRIPTION
These Submersible Sump Pumps are designed for home
sumps. The unit is equipped with a 3-prong grounding-type
power cord. The shaded-pole motor is oil filled and sealed for
cooler running. Upper sleeve/lower ballbearing on the motor
shaft never need lubrication. Automatic reset thermal
protection.
SPECIFICATIONS
Power supply required........................................115V, 60 HZ.
Liquid Temp. Range ..........................32°F to 130°F (0°-54°C)
Individual Branch Circuit Required:...........................15 Amps
Discharge ..............................................................1-1/2" NPT
MOTOR & CORD SPECIFICATIONS
Full
Model
Motor
Load
Number
HP
Amps
HP33
1/3
9.8
HP33-20
1/3
9.8
HP33-30
1/3
9.8
HP50
1/2
12.0
HP50-20
1/2
12.0
HP50-30
1/2
12.0
PERFORMANCE
GPM (LPM) AT TOTAL FEET (m)
5
Model
(1.5m)
(3m)
CAPACITY GALLONS(L)/MINUTE
48
40
HP33
(182)
(151)
62
52
HP50
(235)
(197)
GENERAL SAFETY INFORMATION
Electrically powered sump pumps normally give many years
of trouble-free service when correctly installed, maintained,
and used. However, unusual circumstances (interruption of
power to the pump, dirt/debris in the sump, flooding that
exceeds the pump's capacity, electrical or mechanical failure
in the pump, etc.) may prevent your pump from functioning
Individual
Branch Circuit
Cord
Required (Amps)
Length
15
15
15
15
15
15
10
15
20
(4.6m)
(6.1m)
29
15
(110)
(57)
45
39
(170)
(148)
normally. To prevent possible water damage due to flooding,
consult your dealer about installing a secondary sump pump,
a DC backup sump pump, and/or a high water alarm. See the
"Troubleshooting Chart" in this manual for information about
common sump pump problems and remedies. For more infor-
mation, see your dealer.
1. Know the pump application, limitations, and potential
hazards.
2. Disconnect the power before servicing.
3. Release all pressure within the system before servicing
any component.
4. Drain all water from the system before servicing.
5. Secure the discharge line before starting the pump. An
unsecured discharge line will whip, possibly causing per-
sonal injury and/or property damage.
6. Check the hoses for a weak or worn condition before
each use. Make certain all connections are secure.
7. Periodically inspect the sump, pump and system compo-
nents. Keep free of debris and foreign objects. Perform
routine maintenance as required.
8. Provide a means of pressure relief for pumps whose dis-
charge line can be shut-off or obstructed.
9. Personal Safety:
a. Wear safety glasses at all times when working with
pumps.
b. Keep the work area clean, uncluttered and properly
lighted – replace all unused tools and equipment.
c. Keep visitors at a safe distance from work area.
d. Make the workshop child-proof – with padlocks, mas-
ter switches, and by removing starter keys.
10. When wiring an electrically driven pump, follow all electri-
cal and safety codes that apply.
11. This equipment is only for use on 115 volt (single
phase) and is equipped with an approved 3-conduc-
tor cord and 3-prong, grounding-type plug.
10'
20'
30'
kill. To reduce risk of electric shock, pull plug before ser-
10'
vicing. Pump is supplied with a grounding conductor and
20'
grounding-type attachment plug. Be sure it is connected
30'
only to a properly grounded grounding-type receptacle.
Where a 2-prong wall receptacle is encountered, it must
be replaced with a properly grounded 3-prong receptacle
installed in accordance with codes and ordinances that
No flow
apply.
at height
shown
This pump has not been investigated for use in swim-
below
ming pool areas.
24 Ft.
12. All wiring should be performed by a qualified electrician.
(7.3m)
13. Make certain the power source conforms to the require-
32 Ft.
(9.8m)
ments of your equipment.
14. Protect the electrical cord from sharp objects, hot sur-
faces, oil, and chemicals. Avoid kinking the cord. Replace
or repair damaged or worn cords immediately.
15. Do not touch an operating motor. Motors can operate at
high temperatures.
16. Do not handle the pump or pump motor with wet hands
or when standing on wet or damp surface, or in water.