MAINTENANCE
WARNING
CAUTION
Regular maintenance guarantees proper operation and performance over time.
Special attention is to be paid to the metal filters : frequent cleaning of the metal filters and their supports ensures that no
flammable grease is accumulated.
CLEANING OF EXTERNAL SURFACES
You are advised to clean the external surfaces of the Range Hood at least once every 15 days to prevent oily substances and
grease from sticking to them.
Alternatively and for all the other types of surfaces, it can be cleaned using a damp cloth, slightly moistened with mild,
liquid detergent or denatured alcohol.
Complete cleaning by rinsing well and drying with soft cloths.
Do not use products that contain abrasive substances or cloths NOT specifically designed for cleaning steel.
The glass panels can only be cleaned with specific, non-corrosive or non-abrasive detergents using a soft cloth.
The Manufacturer declines all responsibility for failure to comply with these instructions.
CAUTION
CLEANING OF INTERNAL SURFACES
Do not clean electrical parts, or parts related to the motor inside the Range Hood, with liquids or solvents.
METAL FILTERS
It is advised to frequently wash the metal filters (at least once a month) leaving them to soak in boiling water and cleaning
solution for 1 hour, taking care not to bend them.
- Do not use corrosive, acid or alkaline detergents.
- Rinse them well and wait for them to be completely dry before reassembling them.
- Washing in a dishwasher is permitted, however, it may cause the metal filter material to darken : to reduce the possibility of
this problem from happening, use low-temperature washes (131 °F/ 55 °C max.).
To remove the perimeter suction panel and the metal filters as shown figure below.
How to remove of the
metal filters
How to remove of
the perimeter suction
panel
Please slowly remove the pin
while supporting it with
ngers so that it will not fall.
Before servicing or cleaning unit, switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
Please wear gloves during the cleaning work.
Be careful when removing the perimeter suction panel in case oil has accumulated on it and
may fall out.
1
1
Piston bar
2
pin
2
4
3
Be sure to check that the pin is attached to the piston bar to
reassemble the perimeter suction panel. If not attached, the
perimeter suction panel cannot be supported at the speci ed
position.
3
5
6
9