About the controls on the dehumidifier.
Controls
NOTE: .When.the.bucket.is.full.or.removed,.the.
controls.cannot.be.set.
Power Pad
.. P ress.to.turn.the.dehumidifier.on.and.off.
..
Filter Timer
.. A fter.250.hours.of.operation,.the.Clean the Filter.
indicator.light.will.glow.to.remind.you.to.clean.
the.filter..Remove.the.filter.and.clean.it..
.. P ress.to.turn.off.the.Clean the Filter.light..See.
the.Care and Cleaning.section.
..
Humidity Set Control Pads
.. T he.humidity.level.can.be.set.within.a.range.of.
35%.RH.(Relative.Humidity).to.80%.RH.(Relative.
Humidity).in.5%.increments.or.at.CO.for.
continuous.operation...To.set.the.unit.for.
continuous.operation,.press.the.▼.pad.until.
the.screen.reads.CO.
.. N OTE: .If.CO.(Continuous).is.selected,.the.
dehumidifier.will.operate.continuously.at..
its.maximum.dehumidification.settings.if.
attached.to.a.hose.to.drain.or.until.the.bucket.
is.full.
.. F or.drier.air,.press.the.▼.pad.and.set.to.
a.lower.percent.value.(%).
.. F or.damper.air,.press.the.▲.pad.and.set.
to.a.higher.percent.value.(%).
Other Features
BUCKET FULL Light
Glows.when.the.bucket.is.ready.to.be.emptied,.or.
when.the.bucket.is.removed.or.not.replaced.in.the.
proper.position.
Alarm
If.the.bucket.is.full.or.missing.for.more.than.3.
minutes,.an.alarm.will.sound.for.about.10.seconds.
to.remind.you.to.empty.and.replace.the.bucket.
Auto Shut Off
4
The.Water.Level.Control.Switch.shuts.off.the.
dehumidifier.when.the.bucket.is.full,.or.when.
4 hour or 2 hour
High, Medium
delay off
and Low fan
indicator lights
indicator lights
Clean the Filter
Continuous operation on
indicator light
indicator light
When.you.first.use.the.dehumidifier,.set.
the.humidity.control.to.45%.or.50%..Allow.at.
least.24.hours.for.the.dehumidifier.to.achieve.
the.humidity.level..If.you.still.have.damper.air.
than.desired,.set.the.humidity.level.to.a.lower.
setting.or.select.Continuous.for.maximum.
dehumidification.
Display
.. S hows.the.set.%.humidity.level.while.setting,.
then.shows.the.actual.(+/–.5%.accuracy).
room.%.humidity.level.
Fan Speed Pad
.. C ontrols.the.fan.speed.
.. P ress.to.select.either.High,.Medium or.Low.fan.
speed.
.. S et.the.fan.control.to.High.for.maximum.
moisture.removal..When.the.humidity..
has.been.reduced.and.quiet.operation.is.
preferred,.set.the.fan.control.to.Medium
or.Low.
Delay Off
.. W hile.the.dehumidifier.is.in.operation,.press.
this.pad.to.set.it.to.automatically.turn.off.in.2.
hours.or.4.hours.
the.bucket.is.removed.or.not.replaced.in.the.
proper.position.. NOTE: .Fan.will.continue.to.run.
approximately.3.minutes.after.bucket.is.removed.
Auto Defrost
When.frost.builds.up.on.the.evaporator.coils,.the.
compressor.will.cycle.off.and.the.fan.will.continue.
to.run.until.the.frost.disappears.
Power Outage
In.the.case.of.a.power.outage.or.interruption,.the.
unit.will.automatically.restart,.in.the.settings.last.
used,.after.the.power.is.restored.
Bucket Full light indicates
bucket needs to be emptied
or is not in place in the unit
Power On
indicator light