Information concerning airborne noise and vibration
The measured values were determined according to
EN60745 and declared in accordance with ISO 4871.
Measured A-weighted sound power level: 100 dB (A).
Measured A-weighted sound pressure level: 89 dB (A).
Uncertainty K: 3 dB (A).
Wear hearing protection.
Vibration total values (triax vector sum) determined
according to EN60745.
Surface grinding:
a
Vibration emission value
Uncertainty K = 1.5 m/s
2
The declared vibration total value has been measured in
accordance with a standard test method and may be used
for comparing one tool with another.
It may also be used in a preliminary assessment of exposure.
WARNING
○ The vibration emission during actual use of the power
tool can diff er from the declared total value depending in
the ways in which the tool is used.
○ Identify safety measures to protect the operator that
are based on an estimation of exposure in the actual
conditions of use (taking account of all parts of the
operating cycle such as the times when the tool is
switched off and when it is running idle in addition to the
trigger time).
● Information about power supply system of nominal
voltage 230 V~
Under unfavorable mains conditions, this power tool
may cause transient voltage drops or interfering voltage
fl uctuations.
This power tool is intended for the connection to a power
supply system with a maximum permissible system
impedance Z
of 0.28 Ohm at the interface point (power
MAX
service box) of the user's supply.
The user has to ensure that this power tool is connected
only to a power supply system which fulfi lls the requirement
above.
If necessary, the user can ask the public power supply
company for the system impedance at the interface point.
NOTE
Due to HiKOKI's continuing program of research and
development, the specifi cations herein are subject to
change without prior notice.
h , AG = 5.2 m/s
2
11
English