Change the Sear Burner Orifice
1.
Use a screwdriver to remove screw from the igniter pin.
2.
Remove two screws on the rear of the searing burner. Lift
the burner starting from the back, as shown.
3.
Use a 6 mm socket wrench or 6 mm nut driver to remove
the orifice.
4.
Replace with the Natural gas orifice.
IMPORTANT: Check that the NG orifice is properly
installed inside of the valve.
5.
Reinstall the sear burner. Make sure the sear burner tube
is inserted into the gas valve, as shown.
6.
Reinstall the two screws to the rear of the searing burner.
7.
Use a screwdriver to reinstall the igniter pin.
31