3. Using a drill bit with an 8 mm diameter, make 8 holes in the wall at the position that
you reserve for installing the chimney and cooker hood body. See Pic 2.
4. Insert wall plugs into the holes that you have drilled for the cooker hood body,
fasten 2 × support screw ST4*40 mm halfway in, leaving them 2 mm out of the wall.
See Pic 2.
5. Hang the cooker hood onto the support screws.See pic 3.
6. Insert self-tap screw ST4*30 mm into the safety holes and fully fasten it to ensure
the cooker hood is well fixed. Note: The two safety vents are positioned on the
back housing, with a diameter of 6mm. See pic 3.
7. Equip the converter to the outlet, and fix by tape.Install the 120mm expansion pipe
to the outlet converter and fixed with cable tie. Lift up expansion pipe till it out of the
wall through the hole on the wall. Note:The expansion is not included in the product.
See Pic 4.
6