AIR SUPPLy
Air
Length of Pipe (ft.)
Flow
CFM
50
10
1/2"
20
3/4"
30
3/4"
40
1"
50
1"
70
1"
Never mount oil and water extractor on or near the air compres­s­or.
During compression, air temperature is greatly increased. As the air cools down to room temperature, moisture condenses in the air line, on
its way to the spray gun. Therefore, always mount the oil and water extractor at a point in the air supply system where the compressed air
temperature is lowest.
Drain air lines­ properly.
Pitch all air lines back­ towards the compressor so that condensed moisture will flow back­ into the air receiver where it can be drained off. Each
low point in an air line acts as a water trap. Such points should be fitted with an easily accessible drain. See diagram above.
TyPES OF INSTALLATION
This spray gun is rugged in construction, and is built to yield exceptional value. The life of this product and the efficiency of its
operation depend upon a k­nowledge of its construction, use and maintenance.
HVLP
Fluid
Siphon
Cup
9003A: Parts Breakdown & Operating Manual
100
150
200
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1-1/4"
1-1/4"
Fluid Control Screw
Air Inlet
Atomization
Pressure
Gauge
Air Hose
Pitch pipe back
toward air receiver
Compressor Unit
Drain
SIPHON FEED CUP HOOKUP
Air pressure for atomization is regulated at
extractor. Amount of fluid is adjusted by fluid
control screw on gun, viscosity of paint, and air
pressure.
Oil and
Water
Extractor

Install drain at
each low point
25 Feet
or More
Oil and Water Extractor should be at least 5 ft.
from the compressor, farther if possible.
Oil & Water
Extractor
Drain
rev. 04/4/06