Venting:
Water might escape from the vent opening during
operation.
Please note!
When installing, never hang the equipment by
the discharge line or by the power cable. The
equipment must be hung up by the provided carry
handle or suspension eyelet, or it must rest on the
bottom of the shaft. To ensure that the equipment
works properly, the bottom of the shaft always
must be free of sludge and other accumulations
of dirt. If the water level is too low, the sludge
in the shaft can quickly dry out and hinder the
equipment from starting. It is necessary therefore
to check the equipment regularly (carry out trial
start-ups).
The pump shaft should be large enough.
5.2 Using the pump in the rain barrel
Fit the supplied pipe set as described and make
sure that the seals between the individual compo-
nents are correctly seated (Fig. 3):
1. Connect the telescopic pipe (8) to the short
extension pipe (7).
2. Screw the complete telescopic pipe to the
longer extension pipe (6) and to the swiveling
connection (9).
Proceed as follows to use the pump in the rain
barrel:
•
Connect the pipe set to the pump.
•
Use the attachment hook (Fig. 3 / Item B) to
hang the pump in the rain barrel. To vary the
height, undo the clamp lever of the telescopic
pipe (Fig. 3 / Item A) and tighten it again when
the desired position is reached. You should
set the length of the telescopic pipe such that
the pump does not touch the bottom. This will
keep dirt away from the pump.
•
The height of the attachment hook can be ad-
justed to between 63 and 108 mm depending
on whether the extension pipe is used or not.
•
If necessary, use a hose to extend the tele-
scopic pipe.
•
To withdraw water, open the stopcock (Fig. 3
/ Item C).
5.3 Mains connection
Danger!
The equipment you have purchased comes with
an earthing-pin plug. The equipment is designed
for connection to a socket outlet with earthing
Anl_GE-PP_5555_RB-A_SPK9.indb 18
Anl_GE-PP_5555_RB-A_SPK9.indb 18
GB
contact for 230-240 V ~ 50 Hz. Make sure that the
socket-outlet is suffi ciently fused (at least 6 A)
and in good working order. Insert the power plug
in the socket-outlet and the equipment is ready
for operation.
6. Operation
You can put the equipment into operation after
you have thoroughly read the installation and ope-
rating instructions. Pay attention to the following
points:
•
Make sure that the equipment is set up secu-
rely.
•
Check that the discharge line is fitted correct-
ly.
•
Make sure that the electrical connection is
230-240 V ~ 50 Hz.
•
Check that the electrical socket-outlet is in
good working order.
•
Make sure that no moisture or water can ever
reach the power connection.
•
Make sure that the equipment does not run
dry.
•
To switch off the equipment, pull the power
plug out of the socket outlet.
Note!
1. Lower the pump into the well or shaft or hang
it in the rain barrel using a securing cable.
2. Connect the mains plug to the socket.
The pump will start immediately after the connec-
tion cable is plugged in.
6.1 Automatic mode:
The pump builds up pressure (e.g. a water tap is
closed) and then switches off automatically. The
integrated non-return valve ensures that the pres-
sure is maintained in the hose until water is drawn
off again. When the pressure drops below 1.2
bar, the pump will switch on again automatically.
6.2 Dry-run safeguard:
The pump will make up to 3 priming attempts if:
-
the pump is started by inserting the mains
plug into the power socket
or
-
medium ceases to be available during opera-
tion.
If the availability of medium ceases, the pump
will go automatically into dry-run safeguard mode
- 18 -
30.04.2020 13:33:22
30.04.2020 13:33:22