CAUTION! To reduce the risk of fire, electric shock or injury to persons during the installation and use
of your pump, it is recommended that basic safety precautions should always be taken, including the
following precaution:
Read all these instructions before starting to operate this product and keep these instructions in a
safe place.
1) GENERAL
The pump has been designed to suck up clear water.
It should be installed in a location that is dry, ventilated and protected from bad weather and heat. The
maximum suction height should not exceed 6metres.
Correctly installed, your pump will function with maximum, output and should meet your requirements
fully: read the following Instructions carefully.
2) TECHNICAL CHARACTERISTTICS
Model
Type
Max suction
Output
Motor power
Power supply
Speed
(rotations / minute)
3) INSTALLATION
a) Important recommendations;
Before connecting to the electrical supply, you must:
Fix the pump firmly to the ground or onto a suitable support. To do this, there are two notches
provided for this purpose in the foot of the pump for securing it with bolts (not supplied).
Check that the mains supply corresponds to that given on the pump's technical table.
WARNING
The warranty does not cover accidents due to poor installation. This pump should be installed according
to the national standards in force (NFC 15100 for France) and by qualified personnel. We advise you to
call in an electrician.
The fixed pipe works to which the pump will be connected must have a separation device with contacts of
at least 3mm opening distance at all poles.
If the pump is used for swimming pools it must be powered by a transformer with circuit breaker (RCCD)
with sensitivity not exceeding 30mA. The pump should not be used in outside fountains, garden ponds
and similar places.
N.B.: This pump is not intended for cleaning or other maintenance operations on swimming pools. When
it is used for swimming pools, it must be installed in an enclosed service area.
The total manometric height should not-exceed 35m. The connection cable should be at least of the type
H05RNF –3 x 1 mm (live, neutral and earth).
b) Electrical connection:
1. Remove the lid from the junction box by loosening the three crosshead screws on the top.
6
User and Maintenance Manual
(Pump PRRBK200 / 516136, model 2CP2000 )
2CP2000
Self-priming
54 m
100 l/min at 7 m
2000 W
230V / 50Hz
2850