Descargar Imprimir esta página

Hansgrohe Croma Select S 180 EcoSmart 272541 Serie Instrucciones De Montaje / Manejo / Garantía página 29

Publicidad

Troubleshooting
Problem
Insufficient water
Crossflow: hot water forced into cold
water supply or vice versa when
mixture is closed
Output temperature does not cor-
respond with temperature marked
on handle
Temperature regulation not possible
Safety stop button not operating
Handle hard to turn
Shower or spout dripping
Maintenance
• Should the volume of water decrease over time,
inspect and clean the filters on the thermostatic
cartridge. After reassembly, set the high temperature
limit stop and justify the handle.
• To prolong the life of the themostatic cartridge,
regularly run it through its full range of temperatures.
Possible Cause
– Supply pressure inadequate
– Cartridge filters dirty
– Showerhead or handshower filter
dirty
– Check valves dirty or worn
– Handle not justified
– Water heater set too low
– (new installation) Hot and cold sup-
plies are reversed
– Thermostatic cartridge dirty or worn – Replace the thermostatic cartridge
– Button and/or spring are dirty or
worn
– Cartridge dirty or worn
– Volume control cartridge dirty or
worn
Solution
– Check water pressure
– Clean the filters
– Clean the filter
– Clean check valves, replace if
necessary
– Justify the handle
– Increase the hot water temperature
– Correct the plumbing
– Clean spring and button, replace if
necessary
– Replace cartridge
– Clean or replace volume control
cartridge
29

Publicidad

loading

Este manual también es adecuado para:

Croma select e 180 ecosmart 272571 serie