CONNECT DUCTWORK
TO HOOD
Use duct tape to make joints secure and air tight.
Duct tape
INSTALL LIGHT BULBS
18
halogen bulbs. Light bulbs are not included with
the hood.
WARNING:
of electric shock, do not connect electrical power
to the hood without both bulbs in place.
FOLLOW ELECTRICAL CODE
19
Complete the electrical wiring according to National
Electrical Code and local codes.
NOTE: This hood must be permanently grounded.
Connect house wiring (120 VAC) to hood wiring.
Installation Instructions
To reduce the risk
CONNECT WIRING
20
Connect house black to hood black wire, house white
to hood white wire, and house ground to hood green/
yellow wire. Securely tighten the strain relief clamp
onto the house wiring.
REPLACE WIRING COVER
21
Replace the wiring cover.
REPLACE FILTERS
22
The installation is complete. Turn on power at service
panel, and test for proper operation.
TROUBLESHOOTING CHECKLIST
If the hood seems to be operating at high speed when
the control is not set on high, or if ventilation seems
Knockouts not removed from hood.
Damper blade not opening.
Reduced airflow because the duct is too small or the
duct length is too long.
The duct is blocked.
Undersized or restrictive wall or roof cap.