Descargar Imprimir esta página

Beta 1498-25A Manual De Uso E Instrucciones página 15

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
OPERATION MANUAL AND INSTRUCTIONS
After setting the battery voltage to the 24V mode, set the charging parameters using the "Function" key:
5A
12.5A
5A
12.5A
This will automatically start the battery charging process.
The additional functionality of the charger can be selected using the "Mode" button as follows:
SHOW
SHOW ROOM function: 13.8V.
ROOM
This function is used to keep all the equipment of the vehicle running during demos in the car
shop. (Only in 12V mode)
SUPPLY
Power supply function: 14.0V.
Keep the "Mode" key pressed for 5 seconds to enable this function, which is used to keep a
vehicle's memory banks active while the battery is being changed or whenever the battery is
disconnected from the vehicle's circuit. (Only in 12V mode)
CAUTION: IN THIS FUNCTION, THE BATTERY CHARGER IS NOT PROTECTED AGAINST
POLARITY REVERSAL. RISK OF DAMAGE!
Charge indicators:
The battery is charging.
The green LED flashes.
The battery is fully charged (100%); the battery charger will switch to the maintenance step, ke-
eping the state of efficiency of the battery constantly monitored, so that it is always at an optimal
level of charge. The green LED is steadily on.
INTERRUPTION OF CHARGE CYCLE IN CASE OF MAINS BLACKOUT
In case of blackouts in the 230V mains, the battery charger saves the work cycle it was performing, in order to restore it automati-
cally as soon as the power supply of the 230V mains is restored. This function is crucially important if the battery charger is used
to charge batteries without the operator supervising the cycle; for example, during very long work cycles (maintenance charges)
or when charging overnight (charges for vehicles that need to be charged daily).
END OF CHARGING
1. Unplug the power supply lead of the battery charger from the mains.
2. Disconnect the output lead with black clamp from the vehicle's earthing point or the negative terminal (-) of the battery.
3. Disconnect the output lead with red terminal from the positive terminal (+) of the battery.
Charge for 24V batteries, 5Ah to 100Ah
Maintenance charge for 24V batteries, 5Ah to 150Ah
Suitable for charging WET and Gel batteries
Charge for 24V batteries, 70Ah to 250Ah
Maintenance charge for 24V batteries, 70Ah to 360Ah
Suitable for charging WET and Gel batteries
Charge for 24V batteries, 5Ah to 100Ah
Maintenance charge for 24V batteries, 5Ah to 150Ah
Suitable for charging AGM-START&STOP and AGM-SPIRAL and EFB batteries
Charge for 24V batteries, 70Ah to 250Ah
Maintenance charge for 24V batteries, 70Ah to 360Ah
Suitable for charging AGM-START&STOP and AGM-SPIRAL and EFB batteries
EN
15

Publicidad

loading