Descargar Imprimir esta página

Power Stroke PS906522MFI Manual Del Operador página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

PRODUCT SPECIFICATIONS
ENGINE
Engine Type ........................................................ 391cc, EFI
Fuel Volume ................................................................ 6 gal.
*Rated output determined by PGMA Standard G300
KNOW YOUR GENERATOR
See Figure 2.
The safe use of this product requires an understanding of the
information on the product and in this operator's manual as well
as a knowledge of the project you are attempting. Before use
of this product, familiarize yourself with all operating features
and safety rules.
AC CIRCUIT BREAKERS
The circuit breakers are provided to protect the generator against
electrical overload. The circuit breaker may be reset by pressing
the circuit breaker reset button.
AIR FILTER
The air filter helps to limit the amount of dirt and dust drawn
into the unit during operation.
CARBON MONOXIDE SENSOR WITH
AUTOMATIC SHUTOFF
The generator's carbon monoxide sensor is designed to monitor
the level of carbon monoxide present during generator opera-
tion. If the unit is positioned incorrectly and carbon monoxide
levels rise to an unsafe level, the LED on the sensor will flash red
and the generator will automatically shut down. Leave the area
immediately and relocate to an open outdoor area. Ventilate the
area thoroughly before occupying again. Ensure the generator is
located in an open, outdoor area and point exhaust away from
occupied structures before restarting.
NOTE: After a shutoff event has occured, the LED will continue
to flash red for up to 20 minutes. Once the generator is relocated
and CO levels are safe, the generator can be restarted even if
the light is still flashing.
BATTERY CHARGING FUSE
The battery charge circuit fuse protects the battery.
BATTERY MAINTAINER
Using the battery maintainer when storing the generator helps
keep your generator's battery charged and ready at all times.
CHECK ENGINE INDICATOR LIGHT
The LED indicator light in the control panel will illuminate to indicate
a fault in the engine's fuel injection system. Please contact customer
service or a qualified service center for assistance.
FEATURES
GENERATOR
Rated Voltage ...................................................120 V/240 V
Rated Amps ................................................... 54.2 A/27.1 A
Rated Output*..........................................................6500 W
Starting Watts ..........................................................8125 W
Rated Frequency ........................................................60 Hz
DIGITAL DISPLAY
The digital display shows AC voltage output, frequency, how
long the engine has been running during the current usage
period, and the total number of hours the unit has been used.
ENGINE SWITCH
The engine switch is used alone or in combination with the
recoil starter grip to start the engine. It is also used to turn the
engine off.
FUEL TANK
The fuel tank has a capacity of 6 gallons.
FUEL VALVE
Fuel flow from the fuel tank to the engine is turned on and off
using the fuel valve.
GROUND TERMINAL
The ground terminal is used to assist in properly grounding the
generator to help protect against electrical shock. Consult with a
qualified local electrician for grounding requirements in your area.
LOW OIL SHUT DOWN PROTECTOR
The low oil sensor causes the engine to stop if the level of
lubricant in the crankcase is insufficient.
OIL CAP/DIPSTICK
Remove the oil fill cap to check and add lubricant to the gen-
erator when necessary.
OIL DRAIN PLUG
When changing the engine lubricant, unscrew and remove the
oil drain plug to allow old engine lubricant to be drained.
RECEPTACLES
Your generator has the following single phase, 60 Hz outlets:
two 120 Volt AC duplex 20 Amp GFCI-protected receptacles,
and one 240 Volt AC, 30 Amp receptacle. These can be used
for operating appropriate appliances, electrical lighting, tools,
and motor loads.
RECOIL STARTER GRIP
The recoil starter grip is used (along with the engine switch) to
start the generator's engine.
Page 11 — English

Publicidad