CAUTION:
Do not place the contact element
against the workpiece with excessive force. Also,
pull the trigger fully and hold it on for 1-2 seconds
after nailing.
Even in the "Single sequential actuation" mode, half-
pulled trigger causes an unexpected nailing, when the
contact element re-contacts the workpiece.
Contact actuation
Pull the trigger first and then place the contact element
against the workpiece.
2
Anti dry fire mechanism
This tool is equipped with an anti dry fire mechanism.
When there are a few nails remaining in the magazine,
the contact arm will be locked in the undepressed posi-
tion to prevent the tool from being activated. When it is
activated, load more nails to resume operation.
Removing jammed nails
CAUTION:
Always return the trigger and dis-
connect the hose before removing jammed nails.
CAUTION:
Do not use deformed nails or nail
strip. Failure to do so causes poor nail feeding.
Follow the procedures in "Removing nails" to remove
the nails in the magazine.
Open the latch and release the door, then remove the
jammed nail.
1
► 1. Latch 2. Door
1
2
MAINTENANCE
CAUTION:
Before attempting to perform
inspection or maintenance, always return the trig-
ger and disconnect the air hose from the tool.
NOTICE:
Never use gasoline, benzine, thinner,
alcohol or the like. Discoloration, deformation or
cracks may result.
Nails
Handle nail strips and their box carefully. If the nail
strips have been handled roughly, they may be out of
shape, causing poor nail feed.
Avoid storing nails in a very humid or hot place or place
exposed to direct sunlight.
Maintenance of nailer
Always check the tool for its overall condition and loose
screws before operation. Tighten as required.
With tool disconnected, make daily inspection to assure
free movement of the contact element and trigger. Do
not use tool if the contact element or trigger sticks or
binds.
When the tool is not to be used for an extended period
of time, lubricate the tool using pneumatic tool oil and
store the tool in a safe place. Avoid exposure to direct
sunlight and/or humid or hot environment.
Maintenance of compressor, air set
and air hose
After operation, always drain the compressor tank and
the air filter. If moisture is allowed to enter the tool,
it may result in poor performance and possible tool
failure.
8 ENGLISH