Descargar Imprimir esta página

Tectro TS 425 Instrucciones De Uso página 130

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46
man_TS(CS)4xx.qxd:man_S18xx 09-01-13 10:56 Page 130
K
TROUBLE SHOOTING TIPS
Malfunctions and Solutions
TROUBLE
Problem
Unit does not start
Unit not cooling or
heating room very
well while air flowing
out from the air con-
ditioner
Fan speed cannot be
changed
TEMP. Indicator is not
shown
4
13
Cause
Power cut
Unit may have become unplugged.
Fuse may have blown.
Battery in Remote controller may have
been exhausted.
Distance remote controller to receiver on
the indoor unit is more than 6 to 7
meters, or there are obstacles in between
the remote controller and the receiver.
The time you have set with timer is incor-
rect.
Inappropriate temperature setting.
Air filter is blocked.
Doors or windows in room are open.
Air inlet or outlet of indoor or outdoor
unit has been blocked.
Compressor 3 minutes delay protection
has been activated.
Defrosting of outdoor unit being perfor-
med.
Airconditioner is in automode
Airconditioner is in dry mode
Airconditioner is in fan mode
Solution
Wait for power to be restored.
Check that plug is securely in wall recepta-
cle.
Replace fuse / reset relay / reset circuitbra-
ker
Replace the battery.
Shorten the distance. Remove possible
obstacles. Aim the remote controller
towards the receiver on the indoor unit.
Wait or cancel timer setting.
Set temperature correctly. For detailed
method please refer to "operation with
remote control" chapter E.
Clean the air filter.
Close the doors or windows.
Clear obstructions away first, then restart
the unit.
Wait.
Fan speed can only be changed in HEAT,
COOL and FAN mode
Temperature cannot be set in FAN mode

Publicidad

loading

Este manual también es adecuado para:

Tscs 425Ts 431Tscs 431