2610048703.qxp_DH1020VC 10/5/17 8:15 AM Page 11
adequate size conductors that is capable
of carrying the current necessary for your
tool must be used. This will prevent
excessive voltage drop, loss of power or
overheating. Grounded tools must use 3-wire
extension cords that have 3-prong plugs and
receptacles.
NOTE: The smaller the gauge number, the
higher the cord capacity.
Auxiliary Handle*
Carrying case*
Extension Cords
If an extension cord is
necessary, a cord with
Accessories
RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
Cord Size in A.W.G.
Tool's
Ampere
Cord Length in Feet
Rating
25
50
3-6
18
16
6-8
18
16
8-10
18
16
10-12
16
16
12-16
14
12
(*= standard equipment)
(**= optional accessories)
-11-
Wire Sizes in mm
Cord Length in Meters
100
150
15
30
60
120
16
14
0.75
0.75
1.5
14
12
0.75
1.0
2.5
14
12
0.75
1.0
2.5
14
12
1.0
2.5
4.0
2
2.5
4.0
4.0