Descargar Imprimir esta página

Wolf ICBWWD30O Guia De Instalacion página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

SPECIFICATIONS
Installation Requirements
The warming drawer must be installed with a Wolf drawer
front, avail able through an authorized Wolf dealer. For local
dealer information, visit the find a showroom section of our
website, wolfappliance.com. Specific installation instruc-
tions are included with the drawer front.
The warming drawer can be installed in a standard or flush
inset application (excludes L series drawer front).
Finish the edges of the opening. They may be visible when
the drawer is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
An anti-tip block must be installed to prevent the warming
drawer from tipping forward when opened.
Model WWD30O is CSA approved for outdoor installations.
INSTALLATION REQUIREMENTS
BASE SUPPORT
Warming Drawer
TRIM OVERLAP
Top, Bottom and Sides
|
4
Wolf Customer Care 800.222.7820
All manuals and user guides at all-guides.com
1
/
"
reveal is
(3)
8
MIN
200 lb
(90 kg)
5
/
"
(16)
8
Electrical
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the back wall and
within the shaded area shown in the illustrations on the
following pages. For ease of installation, the electrical
supply for the warming drawer can be placed in an adjacent
cabinet within reach of the power cord.
IMPORTANT NOTE:
When installed outdoors, a ground fault
circuit interrupter (GFCI) is required to reduce the risk of
electrical shock.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
Power Cord
RATING
PLATE
Rating plate location.
grounded, 120 VAC, 60 Hz
15 amp dedicated circuit
3-prong grounding-type
3'
(.9 m)

Publicidad

loading