CONNECT THE WIRING
WARNING: To reduce the risk of electric shock,
make sure power is switched off at the service
panel. Lock or tag service panel to prevent power
from being switched on accidentally.
1
Connect House Wiring (120 VAC) to hood. Use a piece of
Cardboard to protect the cooktop, if necessary.
2
Connect house black to hood black wire, house white to hood
white wire, and house ground under Green Ground Screw.
Securely tighten cable clamp onto house wiring.
INSTALL THE HOOD
HOUSE
WIRING
(120 VAC)
1
2
3
GREEN
GROUND
SCREW
4
!
5
MOUNTING SCREW (4)
Hang hood from (4) Mounting Screws. Slide hood towards
wall until mounting screws are engaged in narrow end of
(4) Keyholes. Tighten mounting screws securely. A long
screwdriver works best.
Replace bottom cover.
Connect ductwork to hood. Use Duct Tape to make joints
secure and air tight.
PAR20, 50W MAX. HALOGEN BULB (2)
Install (2) PAR20, 50 W Maximum Halogen Bulbs. Purchase
bulbs separately.
CAUTION:
Bulbs may be hot! Refer to bulb packaging
for further information.
Replace filters, turn on power at service panel, and test for
proper operation.