MODEL: IOS-DPBIF2
Ratings:
Incandescent / Tungsten: 25W-500W-120VAC.
Fluorescent / Ballast: 500VA-120VAC
Motor: 1/8HP-120VAC
Time Delay: 15 Sec to 30 Min
Operation Temperature: 32˚F--131˚F / 0-55˚C
No minimum Load required.
INSTALLATION INSTRUCTIONS
Description:
The passive infrared sensors work by detecting the difference between heat emitted from the human body in motion
and the background space. The sensor switch can turn a load ON and hold it as long as the sensor detects occupancy.
After no motion is detected for the set time delay, the load turns off automatically. The sensor switch has one relay
(equal to single pole switch).
Coverage Area:
The coverage range of the sensor switch is specified and illustrated in Figure 1. Large objects and some transparent
barriers like glass windows will obstruct the sensor's view and prevent detection, causing the light to turn OFF even
though someone is still in the detection area.
LOCATION/MOUNTING
Since this device responds to temperature changes, care should be taken when mounting the device.
DO NOT mount directly above a heat source, in a location where hot or cold drafts will blow directly on the sensor, or
where unintended motion will be within sensor's field-of-view.
INSTALLATION
1. Connect lead wires as shown in WIRING DIAGRAM (see Figure 2): Black lead to Line (Hot), Red lead to Load wire,
White Lead to Neutral wire, Green lead to Ground.
2. Gently position wires in wall box, attach sensor switch to the box.
3. Mount device "TOP" up.
4. Restore power at circuit breaker or fuse, wait one minute.
5. Remove the small cover plate. (Illustrated as Figure 3.)
6. Locate the adjustment knobs on the control panel to perform test and adjustments.
(Illustrated as Figure 4.)
7. Replace the small cover plate after testing and adjusting.
8. Attach the wallplate.
NOTE: If twist on wire connector is provided, use to join one supply conductor with one 16 AWG device control lead.
ADJUSTMENT
Time Delay Knob
Default position: 15 Seconds (Test mode)
Adjustable: from 15 Seconds to 30 Minutes (clockwise)
Sensor Sensitivity Range Knob
Default position: Center at 65%
Adjustable: 30% (Position 1) to 100% (Position 4)
Note: Turn clockwise for larger rooms. Turn counter clockwise to avoid false alerts in smaller rooms or near doorway or heat source.
OPERATION
Manual On/OFF Button:
By Pushing in the button, the Load can be turned ON/OFF as illustrated in Figure 5.
Turning On the Load
Manually turn ON the Load by pushing the button whenever the Load is OFF.
Turning Off the Load
Manually turn OFF the Load by pushing the button. Without pushing the button, the Load is to be turned OFF after set time delay.
Turning On the Load
Only after the Load automatically turns OFF, the Load can be turned ON automatically if occupancy is detected within 30 second.
IOS-DPBIF2
WARNING
Risk of Fire, Electrical Shock or Personal Injury
• Turn OFF power at circuit breaker or fuse and test that the power is OFF before wiring.
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are not sure about any part of these instructions, consult a qualified electrician.
• Use this device only with copper or copper clad wire.
INDOOR USE ONLY
•
Vacancy
Sensor Switch
Top View
18'
Maximum: 980 sq.ft.
9'
9'
18'
Side View
5'
4'
150˚ Field of View
15'
Figure 1
Wiring Diagram
Neutral
White
Load
Hot
Red
Black
Neutral (White)
Ground
Green
Figure 2
Figure 3
Figure 4
Press
Figure 5
Press
OFF
Figure 6
30'
LOAD
ON