OPERATION
Continued
Note: If pilot goes out, repeat steps 4 thru
7. Wait one (1) minute before lighting pilot
again.
9. Turn control knob counterclockwise
to desired heating level. The main
burner should light. Manual control heat-
ers should be used in locked positions.
10. To leave pilot lit and shut off burners only,
turn control knob clockwise
PILOT position.
WARNING: Always operate
manual control heaters at the
locked positions. Operation
between these positions may
create a possible health hazard
if used in a poorly ventilated
room. Read owner's manual for
complete instructions.
Ignitor Button
Control Knob
Figure 17 - Control Knob In The OFF
Position (Manual Control Models)
Ignitor Button
Control Knob
Figure 18 - Control Knob In The OFF
Position (Thermostat Models)
Thermocouple
Ignitor Electrode
Figure 19 - Pilot (pilot may vary from
illustration)
14
All manuals and user guides at all-guides.com
just heating levels by using the
equipment shutoff valve.
1. Turn control knob clockwise
2. Turn off any electric power to the appli-
to the
3. Close equipment shutoff valve (see Figure
1. Remove front panel (see page 10).
2. Follow steps 1 through 7 under Lighting
3. With control knob pressed in, strike match.
4. Keep control knob pressed in for 30 sec-
OFF
5. Replace front panel.
Thermostat models only
The thermostatic control used on these models
differs from standard thermostats. Standard
thermostats simply turn on and off the burner.
The thermostat used on this heater senses
the room temperature. At times the room may
exceed the set temperature. If so, the burner
will shut off. The burner will cycle back on when
room temperature drops below the set temper-
ature. The control knob can be set to any heat
level between 1 and 5. This adjusts the amount
of gas flow to the burner. This increases or
decreases the burner flame height.
Pilot Burner
Note: The thermostat sensing bulb mea-
sures the temperature of air near the heater
cabinet. This may not always agree with
room temperature (depending on housing
construction, installation location, room size,
open air temperatures, etc.). Frequent use of
your heater will let you determine your own
comfort levels.
www.desatech.com
CAUTION: Do not try to ad-
TO TURN OFF GAS
TO APPLIANCE
OFF position.
ance if service is to be performed.
14, page 12.
MANUAL LIGHTING
PROCEDURE
Instructions, page 13.
Hold match to pilot until pilot lights.
onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 9,
under Lighting Instructions, column 2.
THERMOSTAT
CONTROL OPERATION
to the
110720-01M

Publicidad

loading