2.5.1
Fitting the vibration tube (Fig. C,
D)
Pull the cotter pin 3 out of the fitting 4. Put
the tube 5 into the fitting and secure it with
the cotter pin.
2.5.2
Starting (Fig. E, F, G)
Cold start:
 Turn the ignition 11 to the position
ON.
 Turn the throttle control 6 to idling
mixture (direction right).
 Open the petrol cock 8 (right position).
 Turn on the choker 7 (left position).
 Now pull at the cable control power-
fully. If the machine doesn't start
you'll have to accelerate a bit.
 When you have accelerated and the
engine runs you have to set idling mix-
ture again.
 Turn off the choker (right position).
 Let the engine run about 3 minutes
before beginning to work.
 Set the required speed and begin to
work.
Warm start:
 Let the choker turned off.
 You have to do the other steps like the
steps of the cold start.
2.5.3
Stopping
Turn back the throttle control to idling
mixture.
Switch off the ignition.
Turn off the petrol cock.
Wait till the machine stands still for de-
positing the tube.
Before storing you have to wait till the
machine gets cold.
2.5.4
Placement of the machine (Fig.
H)
Place the machine on a flat ground.
Pull the lock bolt 12 upwards.
Turn the machine a bit so that you can
release the bolt without locking the ma-
chine again.
Before transporting the machine the next
time, it must be locked again.
All manuals and user guides at all-guides.com
2.6
Maintenance
A T T E N T I O N –
D A N G E R !
No
cleaning,
maintenance when machine is run-
ning
Be safe: Shut off the machine, let it cool
down, disconnect spark plug cap from
spark plug.
The machine does not require intense mainte-
nance. However, to ensure a long lifespan, we
strongly recommend following the upkeep and
maintenance plan.
Repairs must be carried out by specialists! Use
original ZIPPER parts only!
2.6.1
Upkeep and maintenance plan
Controls for the maintenance of the machine
Loose or lost
screws, nuts, bolts
Damage of any part
of the machine
Controlling the oil
level
Machine cleaning
Clean spark plug
Clean air filter
2.6.2
Refuelling
The machine is run by unleaded petrol.
Ensure yourself that no particles get into
the fuel tank when refuelling, so always
use the filter that is under the tank cover
9. Use unleaded petrol because it is better for
the environment than leaded ones.
upkeep,
checks
or
Regularly prior to
each operation
Regularly prior to
each operation
Regularly prior to
each operation
Regularly after op-
eration
Every 25 working
hours
Every 20-30 work-
ing hours